摘要

A novel fiber optic hydrogen sensor was proposed and experimentally demonstrated. The sensing element was a fiber Bragg grating (FBG) covered with Pt-loaded WO_3 coating annealed at 315℃ for 1 h. At room temperature of 25℃, the FBG hydrogen sensor has 448 pm wavelength shift toward 8000 ppm hydrogen, and it can detect hydrogen as low as 200 ppm. Experimental results show that ambient humidity has little effect on the performance of the FBG hydrogen sensor, whereas the sensitivity of the FBG hydrogen sensor will be decreased at lower ambient temperatures. The relationship between the wavelength shift of the proposed sensor and hydrogen concentration is proposed and discussed in this article.
机译:提出了一种新型的光纤氢传感器并进行了实验验证。传感元件是光纤布拉格光栅(FBG),覆盖有载有Pt的WO_3涂层,并在315℃下退火1小时。 FBG氢气传感器在25℃的室温下,向8000 ppm氢气的波长偏移为448 pm,它可以检测到200 ppm的氢气。实验结果表明,环境湿度对FBG氢传感器的性能影响很小,而FBG氢传感器的灵敏度在较低的环境温度下会降低。本文提出并讨论了所提出的传感器的波长偏移与氢浓度之间的关系。