We describe a system designed to perform fixed-wavelength absorption spectroscopy of H2O vapor in practical combustion devices. The system includes seven wavelength-stabilized distributed feedback (WSDFB) lasers, each with a spectral accuracy of +/- 1 MHz. An on-board external cavity diode laser (ECDL) that tunes 1320-1365 nm extends the capabilities of the system. Five system operation modes are described. In one mode, a sweep of the ECDL is used to monitor each WSDFB laser wavelength with an accuracy of +/- 30 MHz. Demonstrations of fixed-wavelength thermometry at 10 kHz bandwidth in near-room-temperature gases are presented; one test reveals a temperature measurement error of similar to 0.43%.
机译:我们描述了一种设计用于在实际燃烧设备中执行H2O蒸气的固定波长吸收光谱的系统。该系统包括七个波长稳定的分布式反馈(WSDFB)激光器,每个激光器的光谱精度为+/- 1 MHz。板载外腔二极管激光器(ECDL)可调谐1320-1365 nm,扩展了系统的功能。描述了五种系统操作模式。在一种模式下,ECDL的扫描用于以+/- 30 MHz的精度监视每个WSDFB激光波长。提出了在近室温气体中以10 kHz带宽固定波长测温的演示;一项测试显示温度测量误差接近0.43%。