Effects of intermittent flows on turbine gas meters accuracy

机译:间歇流量对涡轮燃气表精度的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Axial turbine gas meters are well known and appreciated instruments for custody transfer metering, when used at suitable conditions (steady-flow). In anomalous flow conditions (no steady state conditions), with perturbations in the flow (i.e. pulsating flows or intermittent flows), the metrological performance of turbine meter can dramatically decady, inducing remarkable systematic errors. In particular, in the case of intermittent on/off flow (i.e. when the flow is abruptly shut off by means of a valve) the turbine wheel slows down after the flow has stopped and consequently a gas volume is measured which is always higher than that which has actually flown through the gas meter.
机译:当在合适的条件下(稳定流量)使用时,轴向涡轮式燃气表是用于贸易交接计量的众所周知的仪器。在异常流量条件下(无稳态条件),在流量扰动(即脉动流量或间歇流量)下,涡轮流量计的计量性能会急剧下降,从而导致明显的系统误差。特别是在间歇性开/关流量的情况下(即,当通过阀门突然关闭流量时),在流量停止后,涡轮会减速,因此所测得的燃气量始终大于实际上已经通过燃气表。