首页> 外文期刊>Molecular & cellular proteomics: MCP >Top down mass spectrometry of < 60-kDa proteins from Methanosarcina acetivorans using quadrupole FTMS with automated octopole collisionally activated dissociation
【24h】

Top down mass spectrometry of < 60-kDa proteins from Methanosarcina acetivorans using quadrupole FTMS with automated octopole collisionally activated dissociation

机译:使用四极杆FTMS和自动八极杆碰撞活化解离,从头孢甲烷单孢菌(Methanosarcina acetivorans)中<60 kDa蛋白质进行自顶向下质谱

获取原文
获取原文并翻译 | 示例
           

摘要

A fragmentation geometry based upon axial acceleration of m/z-selected protein ions into a linear octopole ion trap allowed simultaneous production and external accumulation of fragment ions prior to m/z measurement in a FT mass spectrometer. Improved dynamic range resulting from this octopole collisionally activated dissociation resulted in a 2.5 x increase in experimental throughput and a 2 x increase in fragment ion matches to gene products identified and characterized in the top down fashion. The acceleration voltage for optimal fragmentation has a m/z and mass dependence, knowledge of which facilitated an automated platform for top down MS/MS on a quadrupole FT hybrid mass spectrometer. Controlled by improved software for data acquisition ( e. g. using dynamic exclusion of previously identified species), automated octopole collisionally activated dissociation of samples fractionated using chromatofocusing and reversed-phase liquid chromatography achieved a significant increase in protein identification rate versus previous benchmarks. Also a batch analysis version of ProSight PTM facilitated probability-based identification of intact proteins obtained in a higher throughput fashion. In total, 101 unique proteins ( 5 - 59 kDa) were identified from whole cell lysates of Methanosarcina acetivorans grown anaerobically, including the characterization of several mispredicted start sites and biologically relevant mass discrepancies.
机译:基于m / z选择的蛋白质离子轴向加速进入线性八极杆离子阱的碎片几何结构允许在FT质谱仪中进行m / z测量之前同时产生碎片离子并在外部积累碎片离子。由八极杆碰撞激活的解离产生的改善的动态范围导致实验通量提高了2.5倍,片段离子匹配与自上而下识别和鉴定的基因产物的匹配度提高了2倍。最佳碎裂所需的加速电压具有m / z和质量依赖性,这方面的知识有助于在四极FT混合质谱仪上为自顶向下的MS / MS提供自动化平台。由用于数据采集的改进软件控制(例如,使用动态排除先前确定的物种),使用色谱聚焦和反相液相色谱法分级分离的样品的自动八极杆碰撞活化离解实现了蛋白质鉴定率相对于先前基准的显着提高。 ProSight PTM的批处理分析版本还有助于以概率为基础的鉴定,以更高的通量方式获得完整蛋白。总共,从厌氧生长的嗜甲烷甲烷八叠球菌的全细胞裂解物中鉴定出101种独特的蛋白质(5-59 kDa),包括表征几个错误预测的起始位点和生物学相关的质量差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号