This study addresses the affect of mounting material used with an encapsulated metallographic specimen on its Rockwell hardness test results. Thirty-five specimens were sectioned from a grade i 144 medium carbon steel rod as the experimental material. Thirty of the sections were encapsulated in six different mounting materials (the test groups), and five were left unencapsu-lated (the control group). Each specimen was ground and polished using the same metallographic preparation procedure, and then hardness tests were performed using the Rockwell hardness C scale. The repeatability (r_(PB)) value, from the ASTM International tnter-Laboratory Study to Establish Precision Statements for ASTM El8, was used to compare the hardness lest results of the encapsulated test groups to the results of the unencapsulated control group. Using that study, if the average hardness of a test group fell within ± r_(PB) of the control group, there would be approximately a 95 % probability that it was equivalent to the control group. Five out of the six test groups (all except transparent thermoplastic) had average hardness values that fell within ± r_(PB) of the control group average. Four of the six test groups (all except green phenolic and transparent thermoplastic) had standard deviations that were less than r_(PB). With such results, green phenolic and transparent thermoplastic are not suitable mounting materials for Rockwell hardness testing.
机译:这项研究解决了封装材料与封装金相试样一起使用对洛氏硬度测试结果的影响。从144级中碳钢棒中切取了35个样品作为实验材料。其中的三十个切片被封装在六种不同的安装材料中(测试组),而五种未被封装(对照组)。使用相同的金相制备程序对每个样品进行研磨和抛光,然后使用洛氏硬度C标尺进行硬度测试。为了确定ASTM El8的精密度声明,使用了ASTM国际检测实验室研究的重复性(r_(PB))值来比较封装试验组与未封装对照组的硬度测试结果。使用该研究,如果测试组的平均硬度落在对照组的±r_(PB)以内,则大约有95%的概率与对照组相当。六个测试组中的五个(除透明热塑性塑料以外的所有测试组)的平均硬度值均在对照组平均值的±r_(PB)范围内。六个测试组中的四个(除绿色酚醛和透明热塑性塑料以外的所有测试组)的标准偏差均小于r_(PB)。有了这样的结果,绿色酚醛和透明热塑性塑料就不是洛氏硬度测试的合适安装材料。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号