首页> 外文期刊>Mikrochimica Acta: An International Journal for Physical and Chemical Methods of Analysis >Ultrasensitive competitive electrochemiluminescence immunoassay for the beta-adrenergic agonist phenylethanolamine A using quantum dots and enzymatic amplification
【24h】

Ultrasensitive competitive electrochemiluminescence immunoassay for the beta-adrenergic agonist phenylethanolamine A using quantum dots and enzymatic amplification

机译:β-肾上腺素能激动剂苯乙醇胺A的超灵敏竞争电化学发光免疫分析法

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

We have designed an ultrasensitive electrochemiluminescence (ECL) immunoassay for the determination of the beta-adrenergic agonist phenylethanolamine A (PA). It is based on the use of L-cysteine-capped CdSe quantum dots (QDs) immobilized on a glassy carbon electrode (GCE) with the help of chitosan. PA (the antigen) was linked to the surface of the GCE by using glutaraldehyde where it competes with the PA in the sample solution to bind to the antibody. Upon formation of the immunocomplex, a second antibody labeled with horseradish peroxidase was immobilized on the surface of the modified GCE. The ECL emission decreases due to steric hindrance by the immunocomplex which slows down the electron transfer rate of the reduction of dissolved oxygen, and this decrease can be strongly amplified by using an enzymatic cycle to consume the self-produced coreactant H2O2. Under optimal conditions, the ECL intensity measured in this competitive immunoassay is related to the concentration of PA over a range as wide as from 0.05 to 1,000 ng mL(-1). The lower detection limit is 15 pg mL(-1) at the S/N ratio of 3. This ECL immunoassay is rapid, sensitive, selective, acceptably precise, and extends the application of QDs-based ECL to immunoassays of beta-agonists.
机译:我们设计了一种超灵敏的电化学发光(ECL)免疫测定法,用于测定β-肾上腺素能激动剂苯基乙醇胺A(PA)。它基于在壳聚糖的帮助下将L-半胱氨酸封端的CdSe量子点(QD)固定在玻璃碳电极(GCE)上的使用。通过使用戊二醛将PA(抗原)连接到GCE的表面,在这里戊二醛与样品溶液中的PA竞争与抗体结合。形成免疫复合物后,将以辣根过氧化物酶标记的第二种抗体固定在修饰的GCE表面。由于免疫复合物的空间位阻,ECL发射减少,这减慢了溶解氧还原反应的电子传递速率,并且可以通过使用酶促循环消耗自生的共反应物H2O2来大大增强这种减少。在最佳条件下,在此竞争性免疫测定中测得的ECL强度与0.05至1,000 ng mL(-1)范围内的PA浓度有关。在3的S / N比下,检测下限为15 pg mL(-1)。该ECL免疫测定是快速,灵敏,选择性,可接受的精确度,并将基于QDs的ECL的应用扩展到β-激动剂的免疫测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号