...
首页> 外文期刊>Microsurgery. >Morphological, hemodynamical and hemorheological changes of mature artificial saphenous arterio-venous shunts in the rat model.
【24h】

Morphological, hemodynamical and hemorheological changes of mature artificial saphenous arterio-venous shunts in the rat model.

机译:大鼠模型中成熟的人工隐性动静脉分流器的形态,血液动力学和血液流变学变化。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Artificial femoral arterio-venous (AV) shunts are widely used in rodent models for studying shunt maturation and to optimize various surgical techniques. However, little is known about complex circulatory, microcirculatory, and hemorheological effects of end-to-side saphenous AV shunts. We aimed to study these parameters in mature AV shunts. Studying these questions in CD rats, end-to-side anastomoses were made between the left saphenous artery and vein. On the right-side the nonoperated saphenous vessels served as own control. Furthermore healthy control animals were also investigated. On the 8th to 12th postoperative week microcirculatory and blood flow measurements were performed and blood samples were taken both from the shunt's arterial and venous limbs and from the nonoperated side vessels. Hematological parameters, erythrocyte aggregation, and deformability were determined. The entire shunt and the control vessels were removed for histological examinations. The skin microcirculation on shunt side slightly increased on thigh and decreased on paws versus the nonoperated side. Blood flow measurements made directly on the vessels showed that arterial to venous blood flow rate ratio was 1.59 +/- 0.29 on nonoperated side and 1.2 +/- 0.13 on the shunt side, and 1.49 +/- 0.05 in control animals. Erythrocyte aggregation and deformability worsened on the shunt side. Histologically increased number of smooth muscle elements and connective tissue were found in venous limb of the shunts. The artificial AV shunt between the saphenous artery and vein seems to be a suitable model for further functional-morphological and hemorheological examinations of hemodialysis in various states and diseases.
机译:人工股动静脉(AV)分流器被广泛用于啮齿动物模型中,以研究分流器成熟度并优化各种手术技术。然而,关于端到端大隐静脉分流的复杂循环,微循环和血液流变学影响知之甚少。我们旨在研究成熟的AV分流器中的这些参数。在CD大鼠中研究这些问题时,在左隐动脉和静脉之间进行了端到端吻合。在右侧,非手术隐性血管用作自己的对照。此外,还研究了健康对照动物。术后第8至12周进行微循环和血流量测量,并从分流的动脉和静脉四肢以及非手术侧血管中采集血样。测定血液学参数,红细胞聚集和可变形性。取出整个分流管和对照血管进行组织学检查。与非手术侧相比,分流侧的皮肤微循环在大腿上略有增加,而爪子则减少。直接在血管上进行的血流测量结果显示,非手术侧的动脉血与静脉血的流量比为1.59 +/- 0.29,分流侧的血流比为1.2 +/- 0.13,对照动物的血流比为1.49 +/- 0.05。红血球聚集和变形能力在分流侧恶化。在组织学上发现分流器的静脉肢中平滑肌元素和结缔组织的数量增加。隐性大动脉和大静脉之间的人工AV分流似乎是在各种状态和疾病下进行血液透析的进一步功能形态学和血液流变学检查的合适模型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号