...
首页> 外文期刊>Mikrochimica Acta: An International Journal for Physical and Chemical Methods of Analysis >Determination of trace rare earth elements by inductively coupled plasma optical emission spectrometry after preconcentration with immobilized nanometer titanium dioxide
【24h】

Determination of trace rare earth elements by inductively coupled plasma optical emission spectrometry after preconcentration with immobilized nanometer titanium dioxide

机译:固定化纳米二氧化钛富集-电感耦合等离子体发射光谱法测定痕量稀土元素。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Nanometer titanium dioxide immobilized on silica gel(immobilized nanometer TiO2)was prepared by the sol-gel method and characterized by X-ray diffraction(XRD)and scanning electron microscopy(SEM).The adsorptive potential of immobilized nanometer TiO2 for rare earth elements(REEs)was assessed in this work.The REE ions can be quantitatively retained by immobilized nanometer TiO2 at a pH range of 6-9,and 0.5 molL~(-1)HNO3 was sufficient for complete elution.A method has been developed for the determination of trace REEs based on preconcentration with a microcolumn packed with immobilized nanometer TiO2 and determination by inductively coupled plasma optical emission spectrometry(ICP-OES).The material showed relatively high chemical stability towards the action of acidic solutions.The packed microcolumn used in proposed procedure did not show any over pressure or swelling and can be used up to at least 20 adsorption-elution cycles without decrease in the performance.The optimum experimental parameters for preconcentration of REEs,such as pH of the sample,sample flow rate and volume,elution solution and interfering ions,have been investigated.The detection limits for REEs was between 3 and 57 ngL~(-1),and the rela-tive standard deviations(RSDs)for the determination of REEs at 10ng mL~(-1)level were found to be less than 6% when processing 100 mL sample solution.The method has been successfully applied to the determination of trace REEs in some environmental samples.
机译:采用溶胶-凝胶法制备了固定在硅胶上的纳米二氧化钛,并通过X射线衍射(XRD)和扫描电子显微镜(SEM)对纳米二氧化钛进行了表征。稀土离子可以通过固定化的纳米TiO2在6-9的pH范围内定量保留REE离子,0.5 molL〜(-1)HNO3足以完全洗脱。固定化纳米TiO2填充微柱预浓缩并电感耦合等离子体发射光谱法(ICP-OES)测定痕量稀土元素。该材料对酸性溶液的作用显示出较高的化学稳定性。程序没有显示任何过压或溶胀,并且可以使用至少20个吸附-洗脱循环而不会降低性能。最佳实验l研究了稀土元素的预浓缩参数,如样品的pH值,样品的流速和体积,洗脱液和干扰离子等。稀土元素的检出限为3〜57 ngL〜(-1),相对在处理100 mL样品溶液时,测定10ng mL〜(-1)浓度的REE的活性标准偏差(RSD)小于6%。该方法已成功地用于某些样品中痕量REE的测定环境样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号