摘要

A new method for the complexometric determination of Bi in the presence of co-ions using 2-mercaptoethanol as selective masking agent has been proposed. Bismuth along with other ions in a given sample solution are initially complexed with excess of EDTA. The pH of the solution is adjusted to 5.0-6.0 using solid hexamine (10 +- 2g) and the remaining uncomplexed EDTA is titrated with lead-nitrate solution using xylenol orange indicator. A known excess of 2-mercaptoethanol solution (5% alcoholic) is then added, the mixture is shaken well and the released EDTA from the Bi(III)-EDTA complex is titrated against standard lead-nitrate solution. The method is applied to the determination of bismuth in Wood's alloy. Reproducible and accurate results are obtained for 2-40 mg of bismuth with relative errors <= 0.5% and standard deviations <= 0.04mg.
机译:提出了一种使用2-巯基乙醇作为选择性掩蔽剂在钴离子存在下络合测定铋的新方法。铋与给定样品溶液中的其他离子最初会与过量的EDTA络合。使用固体六胺(10±2 g)将溶液的pH值调节至5.0-6.0,并使用二甲酚橙指示剂用硝酸铅溶液滴定剩余的未络合EDTA。然后加入已知过量的2-巯基乙醇溶液(5%乙醇),将混合物充分振摇,然后用标准的硝酸铅溶液滴定从Bi(III)-EDTA络合物中释放的EDTA。该方法适用于伍德合金中铋的测定。对于2-40 mg的铋,可得到可重复且准确的结果,相对误差<= 0.5%,标准偏差<= 0.04mg。