首页> 外文期刊>Mikrochimica Acta: An International Journal for Physical and Chemical Methods of Analysis >Column Solid-Phase Extraction with 2-Acetylmercaptophenyldiazoaminoazobenzene (AMPDAA) Impregnated Amberlite XAD-4 and Determination of Trace Heavy Metals in Natural Waters by Flame Atomic Absorption Spectrometry
【24h】

Column Solid-Phase Extraction with 2-Acetylmercaptophenyldiazoaminoazobenzene (AMPDAA) Impregnated Amberlite XAD-4 and Determination of Trace Heavy Metals in Natural Waters by Flame Atomic Absorption Spectrometry

机译:2-乙酰基巯基苯基重氮氨基偶氮苯(AMPDAA)浸渍Amberlite XAD-4柱固相萃取并通过火焰原子吸收光谱法测定天然水中的痕量重金属

获取原文
获取原文并翻译 | 示例
           

摘要

A column solid-phase extraction (SPE) preconcentration method was developed for the determination of Cd,Co,Cu,Ni and Zn ions in natural water samples by flame atomic absorption spectro-metry.The procedure is based on the retention of analytes in the form of 2-acetylmercaptophenyl-diazoaminoazobenzene (AMPDAA) complexes on a short column of AMPDAA-XAD-4 resin from buffered sample solution and subsequent elution with hydrochloric acid plus sodium chloride.Important SPE parameters were optimized using model solutions.The loading half-time,t_(1/2),for Cd,Co,Cu and Zn was found to be less than 5 min,and for Ni the value was 12 min.The detection limit for Cd,Co,Cu,Ni and Zn was 0.028,0.064,0.042,0.023 and 0.16 mug L~(-1),respectively,and the quantification limit was 0.043,0.11,0.099,0.044 and 0.29 mug L~(-1),respectively.The AMPDAA-XAD-4 resin has good selectivity for Cd,Co,Cu,Ni and Zn over several electrolytes,especially over earth alkaline metals with tolerance limits of 0.05 mol L~(-1).The method was validated by analysing a standard reference material (GBW 08301),and it was found that the results agree with those quoted by the manufactures.The developed method was applied to the determination of trace metal ions in tap water and river water samples with satisfactory results.
机译:建立了一种柱固相萃取(SPE)富集方法,通过火焰原子吸收光谱法测定天然水样品中的Cd,Co,Cu,Ni和Zn离子。缓冲液中的AMPDAA-XAD-4树脂短柱上形成2-乙酰基巯基苯基-重氮氨基偶氮苯(AMPDAA)配合物,然后用盐酸和氯化钠洗脱,使用模型溶液优化重要的SPE参数,上样时间,t_(1/2),对于Cd,Co,Cu和Zn小于5分钟,对于Ni为12分钟。Cd,Co,Cu,Ni和Zn的检出限为0.028,分别为0.064、0.042、0.023和0.16马克杯L〜(-1),定量限分别为0.043、0.11,0.099、0.044和0.29马克杯L〜(-1)。AMPDAA-XAD-4树脂具有良好的几种电解质对Cd,Co,Cu,Ni和Zn的选择性,特别是对公差范围为0.05 mol L〜(-1)的碱土金属。该方法通过分析标准参考物质(GBW 08301)进行了验证,结果与制造商引用的结果相符。该方法用于自来水和河水样品中痕量金属离子的测定满意的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号