首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >Novel fabricated silver particles/polypyrrole printed circuit board passive samplers for volatile organic compounds monitoring
【24h】

Novel fabricated silver particles/polypyrrole printed circuit board passive samplers for volatile organic compounds monitoring

机译:新型制造的银颗粒/聚吡咯印刷电路​​板无源采样器,用于监测挥发性有机化合物

获取原文
获取原文并翻译 | 示例

摘要

A simple fabricated silver particles/polypyrrole printed circuit board (PCB) was successfully developed as a passive sampler for the monitoring of the volatile organic compounds, xylene and styrene. The surface morphology of the PCB passive sampler was investigated by SEM, and a cauliflower-like structure with large surface area was obtained. After sampling, the adsorbed analytes were easily desorbed by laboratory-built thermal desorption device coupled with an on-line micro-preconcentrator and analyzed by GC-FID. Under optimum conditions, a wide linear dynamic range (0.002-10.849ng for xylene and 0.002-10.643ng for styrene with R~2>0.99) was obtained with a low limit of detection (0.65 and 0.64pg for xylene and styrene, respectively) and a low limit of quantitation (2.00pg for both compounds). The developed PCB passive samplers provided a good sampler-to-sampler reproducibility with a %RSD of less than 8%, a 2weeks storage stability, a four times reusability with a %RSD of less than 10% and an especially low cost of only 0.25 USD per sampling. The obtained results were comparable to those using a commercial passive sampler. The developed passive samplers were used to monitor xylene and styrene at two copy-print shops in Hat Yai, Songkhla, Thailand. It was found that only xylene was found in the copy-print room ranging from N.D. to (3.0±0.1) ppbV. In addition, a personal exposure was also monitored and only xylene (1.4-3.4ppbV) was also detected.
机译:成功开发了一种简单的银颗粒/聚吡咯印刷电路​​板(PCB)作为被动采样器,用于监测挥发性有机化合物,二甲苯和苯乙烯。用扫描电镜(SEM)研究了PCB无源采样器的表面形态,得到了具有大表面积的菜花状结构。取样后,吸附的分析物很容易通过实验室内置的热脱附设备与在线微量预浓缩器相结合进行脱附,并通过GC-FID进行分析。在最佳条件下,获得了很宽的线性动态范围(二甲苯为0.002-10.849ng,苯乙烯为0.002-10.643ng,R〜2> 0.99),并且检测限较低(二甲苯和苯乙烯分别为0.65和0.64pg)定量下限低(两种化合物均为2.00pg)。已开发的PCB无源采样器提供了良好的采样器到采样器重现性,%RSD小于8%,2周的存储稳定性,四次可重用性,%RSD小于10%,特别低的成本仅为0.25每次采样美元。获得的结果与使用商用无源采样器的结果相当。在泰国宋卡府合艾的两家复印店,开发的无源采样器用于监测二甲苯和苯乙烯。发现在复印室中从N.D.到(3.0±0.1)ppbV范围内仅发现二甲苯。此外,还监测了个人暴露情况,并且仅检测到二甲苯(1.4-3.4ppbV)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号