Reliable certified reference materials (CRM) are required for neutron dosimetry in k(0)-neutron activation analysis (k(0)-NAA). In the past, levitation melting was employed to produce highly homogeneous alloys used in the production of CRMs. This publication describes a novel and more efficient way of processing such alloys using the example of an Al-Au alloy, the evaluation of the efficacy with respect to achieving homogeneity and avoiding micro- and macrosegregation and the final certification of the Au mass fraction. First, Al-5% Au alloy was melted by arc melting and then diluted into Al-0.1% Au with high purity Al in a resistance furnace under the protection of high purity argon gas. The as-casted Al-0.1% Au was then heat-treated at about 635 degrees C for 48 h. No significant macrosegregation and no intermetallic phase (AuAl2) were observed in the heat-treated alloy. Using this approach, a new CRM for gold mass fraction in A1-0.1% Au was produced in the form of wires and foils (ERM-EB530A, B and C). The relative uncertainty from gold inhomogeneity in the material was assessed using a randomised block design and inductively coupled plasma optical emission spectrometry (ICP-OES) and was found to be 03%. The characterisation of the gold mass fraction was performed by an interlaboratory comparison of expert laboratories. Sixteen laboratories participated using instrumental neutron activation analysis (Au-197(n,gamma)Au-198), fire assay and ICP-OFS. Alternative INAA reactions (Au-197(n,2n)Au-196) and calibration strategies were tested but not retained for the characterisation study as they did not meet the strict performance criteria set for the study. After evaluation of homogeneity and characterisation, the Au mass fraction in ERMEB530A, B and C was certified to be 1005 +/- 7 mg/kg (k = 2), which is a lower uncertainty than for previous similar materials. This demonstrates the suitability of the new production route, which should also be applicable to other binary alloys required for neutron dosimetry. (C) 2015 Elsevier B.V. All rights reserved.
机译:k(0)-中子活化分析(k(0)-NAA)中的中子剂量测定需要可靠的认证参考材料(CRM)。过去,悬浮熔炼用于生产用于CRM的高度均质合金。该出版物描述了一种以Al-Au合金为例的新型且更有效的加工此类合金的方法,评估了在实现均质性和避免微观和宏观偏析方面的功效以及Au质量分数的最终证明。首先,通过电弧熔化将Al-5%Au合金熔化,然后在高纯氩气的保护下在电阻炉中将其稀释成Al-0.1%Au和高纯Al。然后将铸态的Al-0.1%Au在约635摄氏度下热处理48小时。在热处理的合金中没有观察到明显的宏观偏析和金属间相(AuAl2)。使用这种方法,以线和箔(ERM-EB530A,B和C)的形式生产了一种新的CRM方法,用于金的质量分数为A1-0.1%Au。使用随机区组设计和电感耦合等离子体发射光谱法(ICP-OES)评估了材料中金不均一性带来的相对不确定性,发现该不确定度为03%。金质量分数的表征是通过专家实验室的实验室间比较进行的。 16个实验室参加了使用仪器中子活化分析(Au-197(n,γ)Au-198),火分析和ICP-OFS的实验。测试了替代的INAA反应(Au-197(n,2n)Au-196)和校准策略,但由于其不符合为研究设定的严格性能标准,因此并未保留用于表征研究。在评估均质性和特性后,ERMEB530A,B和C中的Au质量分数被证明为1005 +/- 7 mg / kg(k = 2),这比以前的类似材料的不确定度要低。这证明了新生产路线的适用性,这也应适用于中子剂量学所需的其他二元合金。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号