The determination of Nb and Ta in Nb-Ta minerals was accomplished by slurry nebulization inductively coupled plasma optical emission spectrometry (ICP-OES), using a clog-free V-groove ceramic nebulizer. Samples were first wet-ground to appropriate particle sizes with narrow size distribution and 90% of the particles in the slurry were smaller than 2.32 mu m in diameter. Subsamples were then dispersed in pH 9 aqueous solutions, and agitated in an ultrasonic bath for 15 min prior to analysis. Due to the lack of slurry standards matching well with the samples, calibration was simply carried out using aqueous solution standards. Results were compared with those obtained from a conventional fusion decomposition procedure and acid digestion procedures and a good agreement between the measured and referred values was obtained. The technique provided a good alternative for the rapid determination of Nb and/or Ta in their corresponding minerals. (c) 2006 Published by Elsevier B.V.
机译:Nb-Ta矿物中Nb和Ta的测定是使用无堵塞的V槽陶瓷雾化器通过浆液雾化电感耦合等离子体发射光谱法(ICP-OES)完成的。首先将样品湿磨成合适的粒径,粒径分布窄,并且浆液中90%的粒径小于2.32微米。然后将子样品分散在pH 9的水溶液中,并在分析之前在超声浴中搅拌15分钟。由于缺乏与样品匹配的浆料标准液,因此只需使用水溶液标准液即可进行校准。将结果与通过常规熔融分解程序和酸消解程序获得的结果进行比较,并获得了实测值与参考值之间的良好一致性。该技术为快速测定相应矿物中的Nb和/或Ta提供了很好的选择。 (c)2006年由Elsevier B.V.发布

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号