首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >Determination of Mo, Zn, Cd, Ti, NiVFe, Mn, Cr and Co in crude oil using inductively coupled plasma optical emission spectrometry and sample introduction as detergentless microemulsions
【24h】

Determination of Mo, Zn, Cd, Ti, NiVFe, Mn, Cr and Co in crude oil using inductively coupled plasma optical emission spectrometry and sample introduction as detergentless microemulsions

机译:电感耦合等离子体发射光谱法和样品引入无洗涤剂微乳液法测定原油中的Mo,Zn,Cd,Ti,NiVFe,Mn,Cr和Co

获取原文
获取原文并翻译 | 示例
           

摘要

A procedure to prepare crude oil samples as detergentless microemulsions was optimized and applied for the determination of Mo, Zn, Cd, Si, Ti, Ni, V, Fe, Mn, Cr and Co by ICP OES. Propan-l-ol was used as a co-solvent allowing the formation of a homogeneous and stable system containing crude oil and water. The optimum composition of the microemulsion was crude oil/propan-l-ol/water/concentrated nitric acid, 6/70/20/4 w/w/w/w. This simple sample preparation procedure together with an efficient sample introduction (using a Meinhard K3 nebulizer and a twister cyclonic spray chamber) allowed a fast quantification of the analytes using calibration curves prepared with analyte inorganic standards. In this case, Sc was used as internal standard for correction of signal fluctuations and matrix effects. Oxygen was used in the nebulizer gas flow in order to minimize carbon building up and background. Limits of detection in the ng g(-1) range were achieved for all elements. The methodology was tested through the analysis of one standard reference material (SRM NIST 1634c, Residual Fuel Oil) with recoveries between 97.9% and 103.8%. The method was also applied to two crude oil samples and the results were in good agreement with those obtained using the acid decomposition procedure. The precision (n=3) obtained was below 5% and the results indicated that the method is well suited for oil samples containing low concentrations of trace elements. (c) 2006 Elsevier B.V. All rights reserved.
机译:优化了制备作为无洗涤剂微乳液的原油样品的程序,并将其用于通过ICP OES测定Mo,Zn,Cd,Si,Ti,Ni,V,Fe,Mn,Cr和Co。丙-1-醇用作助溶剂,允许形成包含原油和水的均匀稳定的体系。微乳液的最佳组成是原油/丙-1-醇/水/浓硝酸6/70/20/4 w / w / w / w。这种简单的样品制备程序以及有效的样品引入(使用Meinhard K3雾化器和旋风旋风雾化室)可以使用分析物无机标准品制备的校准曲线对分析物进行快速定量。在这种情况下,将Sc用作校正信号波动和矩阵效应的内标。雾化器气流中使用氧气是为了最大程度地减少积碳和背景。所有元素的检测限均在ng g(-1)范围内。通过分析一种标准参考物质(SRM NIST 1634c,残余燃油)对方法学进行了测试,回收率在97.9%至103.8%之间。该方法还应用于两个原油样品,结果与使用酸分解程序获得的结果吻合良好。获得的精度(n = 3)低于5%,结果表明该方法非常适合于痕量元素含量低的油样。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号