In the present work the establishment of optimal storage condition for brain samples has been one of our aims. Storage should minimize alterations of the sample due to losses and contamination. The second aim was to investigate the applicability of microwave heating for dissolution of brain samples. Eleven elements (Na, K, Mg, Ca, P, S, Al, Cu, Mn, Sr, Zn) were measured in nine different regions from both hemispheres of nine deep-frozen normal human brains. Simultaneous multielement analyses were carried out by inductively coupled plasma atomic emission spectrometry (ICP-AES) and instrumental neutron activation analysis (INAA). The precision and accuracy were evaluated by analyzing certified standard reference materials. Our results showed that microwave acid digestion is a valuable method for the preparation of human brain samples for ICP-AES analysis. Compared to Parr bomb digestion in a regular oven, microwave digestion is much faster, although it provides essentially the same precision and accuracy. (C) 1995 Academic Press, Inc. [References: 7]
机译:在目前的工作中,建立脑样本的最佳储存条件一直是我们的目标之一。储存应尽量减少由于损失和污染引起的样品变化。第二个目的是研究微波加热对脑样本溶解的适用性。在九个深度冷冻的正常人脑的两个半球的九个不同区域中,测量了11种元素(Na,K,Mg,Ca,P,S,Al,Cu,Mn,Sr,Zn)。通过电感耦合等离子体原子发射光谱法(ICP-AES)和仪器中子活化分析(INAA)进行了同时的多元素分析。通过分析认证的标准参考物质评估准确性和准确性。我们的结果表明,微波酸消解是制备用于ICP-AES分析的人脑样品的有价值的方法。与常规烤箱中的帕尔炸弹消解法相比,微波消解法要快得多,尽管它提供了基本相同的精度和准确性。 (C)1995 Academic Press,Inc. [参考:7]