Obtaining discrete data is inseparably connected with losing information on surface properties. In contact measurements, the ball tip functions as a mechanical-geometrical filter. In coordinate measurements the coordinates of the measurement points of a discrete distribution on the measured surface are obtained. Surface geometric deviations are represented by a set of local deviations, i.e. deviations of measurement points from the nominal surface (the CAD model), determined in a direction normal to this surface. The results of measurements depend both on the ball tip diameter and the grid size of measurement points. This article presents findings on the influence of the ball tip diameter and the grid size on coordinate measurement results along with the experimental results of measurement of a free-form milled surface, in order to determine its local geometric deviations. One section of the surface under research was measured using different measurement parameters. The whole surface was also scanned with different parameters, observing the rule of selecting the tip diameter d and the sampling interval T in the ratio of 2:1.
机译:获得离散数据与丢失表面特性信息密不可分。在接触测量中,球形尖端充当机械几何过滤器。在坐标测量中,获得被测表面上离散分布的测量点的坐标。表面几何偏差由一组局部偏差表示,即在垂直于该表面的方向上确定的测量点与标称表面(CAD模型)的偏差。测量结果取决于球头直径和测量点的网格大小。本文介绍了有关球头直径和网格尺寸对坐标测量结果的影响的发现,以及测量自由形状铣削表面的实验结果,以确定其局部几何偏差。使用不同的测量参数对正在研究的表面的一部分进行了测量。还用不同的参数扫描整个表面,遵守以2:1的比率选择尖端直径d和采样间隔T的规则。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号