The joule balance in NIM of China

机译:中国NIM中的焦耳平衡

获取原文
获取原文并翻译 | 示例
           

摘要

The advantage of the joule balance over the classic watt balance is that the dynamic measurement in the watt balance is replaced by a static measurement, which makes the whole measurement procedure easier. The main problems in the joule balance are the precise measurement of mutual inductance and coil heating. These problems and recent progress in the development of the joule balance are described and discussed in this paper. The whole system is at the stage of being adjusted and improved. The principle of the joule balance has been demonstrated by a measurement of the Planck constant, h = 6.626 104(59) × 10~(-34) J s with an 8.9 ppm measurement uncertainty.
机译:焦耳天平相对于经典瓦特天平的优势在于,瓦特天平中的动态测量被静态测量代替,这使整个测量过程变得更加容易。焦耳平衡中的主要问题是互感和线圈发热的精确测量。本文将对这些问题以及焦耳秤开发的最新进展进行描述和讨论。整个系统正处于调整完善的阶段。焦耳平衡的原理已通过测量普朗克常数h = 6.626 104(59)×10〜(-34)J s证明,测量不确定度为8.9 ppm。