An intercomparison of the melting temperatures of four Pd-C eutectic fixed-point cells was performed using four Pt/Pd thermocouples. The cells are designed for the calibration of thermocouples and were constructed in the participating laboratories of NPL, LNE, NMIJ and PTB. The measurements were performed in four different high-temperature furnaces but by applying the same measurement procedure. In spite of slightly different cell designs and different material sources, the melting temperatures of three of the four Pd-C cells (NPL, LNE and NMIJ) agreed very well within their expanded uncertainties of k velence 2.
机译:使用四个Pt / Pd热电偶对四个Pd-C共晶定点电池的熔化温度进行了比较。这些电池专为校准热电偶而设计,并在NPL,LNE,NMIJ和PTB的参与实验室中构建。在四个不同的高温炉中进行测量,但是采用相同的测量程序。尽管电池设计和材料来源略有不同,但四个Pd-C电池中的三个(NPL,LNE和NMIJ)的熔化温度在其kvelence 2扩展不确定性范围内非常吻合。