摘要

This paper discusses on the shaking table test results of two 1:4 scale model of two-storymasonry structure typically used in constructing low-rise residential buildings. This test is performed to provide a better understanding of the seismic behavior of the PP-band (polypropylene band) mesh retrofitted adobe masonry house. The test structure is subjected to a series of different levels of harmonicmotion that applied along the longitudinal direction. The results of the shaking table tests on building models show that the PP-band retrofitting technique can enhance the safety of masonry buildings, even during severe ground motion.
机译:本文讨论了通常用于建造低层住宅的两种两层砌体结构的1:4比例模型的振动台测试结果。进行该测试的目的是为了更好地理解PP带(聚丙烯带)网格改造的土坯砌体房屋的抗震性能。对测试结构进行沿纵向施加的一系列不同级别的谐波运动。在建筑模型上进行的振动台测试结果表明,即使在剧烈的地面运动中,PP箍改型技术也可以提高砖石建筑的安全性。