首页> 外文期刊>British journal of anaesthesia >Effect of positive end-expiratory pressure on pulmonary shunt and dynamic compliance during abdominal surgery
【24h】

Effect of positive end-expiratory pressure on pulmonary shunt and dynamic compliance during abdominal surgery

机译:呼气末正压对腹部手术中肺分流和动态顺应性的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Background: General anaesthesia decreases pulmonary compliance and increases pulmonary shunt due to the development of atelectasis. The presence of capnoperitoneum during laparoscopic surgery may further decrease functional residual capacity, promoting an increased amount of atelectasis compared with laparotomy. The aim of this study was to evaluate the effects of different levels of positive end-expiratory pressure (PEEP) in both types of surgery and to investigate whether higher levels of PEEP should be used during laparoscopic surgery.
机译:背景:由于肺不张的发展,全身麻醉会降低肺顺应性并增加肺分流。与剖腹手术相比,腹腔镜手术中腹膜盖膜的存在可能进一步降低功能残余能力,从而导致肺不张的增加。这项研究的目的是评估两种类型的手术中不同水平的呼气末正压(PEEP)的效果,并研究在腹腔镜手术中是否应使用更高水平的PEEP。