首页> 外文期刊>Medical engineering & physics. >The effect of motion patterns on edge-loading of metal-on-metal hip resurfacing.
【24h】

The effect of motion patterns on edge-loading of metal-on-metal hip resurfacing.

机译:运动模式对金属对金属髋关节表面重铺边缘载荷的影响。

获取原文
获取原文并翻译 | 示例

摘要

The occurrence of pseudotumours (soft tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty (MoMHRA) has been associated with high serum metal ion levels and consequently higher than normal bearing wear. We investigated the relationship between serum metal ion levels and contact stress on the acetabular component of MoMHRA patients for two functional activities; gait and stair descent. Four subjects with MoMHRA, who had their serum metal ion levels measured, underwent motion analysis followed by CT scanning. Their motion capture data was combined with published hip contact forces and finite element models representing 14% (peak force) and 60% (end of stance) of the gait cycle and 52% (peak force) of stair descent activity were created. The inclination angle of the acetabular component was increased by 10 degrees in 1 degrees intervals and the contact stresses were determined at each interval for each subject. When the inclination angle was altered in such a way as to cause the hip contact force to pass through the edge of the acetabular component edge-loading occurred. Edge-loading increased the contact stress by at least 50%; the maximum increase was 108%. Patients with low serum metal ion levels showed no increase in contact stress at peak force during gait or stair descent. Patients with high serum metal ion levels exhibited edge-loading with an increase to the inclination angle of their acetabular components. The increase in inclination angle that induced edge-loading for these subjects was less than the inter-subject variability in the angle of published hip contact forces. The results of this study suggest that high serum metal ion levels are the result of inclination angle influenced edge-loading but that edge-loading cannot be attributed to inclination angle alone and that an individual's activity patterns can reduce or even override the influence of a steep acetabular component and prevent edge-loading.
机译:金属对金属的髋关节表面置换术(MoMHRA)后出现假瘤(与髋关节相关的软组织肿块)与较高的血清金属离子水平相关,因此高于正常的轴承磨损。我们调查了MoMHRA患者的两种功能活动的血清金属离子水平与髋臼组件接触压力之间的关系。步态和楼梯下降。对四名患有MoMHRA的受试者进行了血清金属离子水平测定,然后对其进行运动分析,然后进行CT扫描。他们的运动捕捉数据与已发布的髋部接触力相结合,并创建了代表步态周期的14%(峰值力)和60%(姿态结束)和52%(峰值力)楼梯下降活动的有限元模型。髋臼组件的倾斜角以1度间隔增加10度,并针对每个对象在每个间隔确定接触应力。当倾斜角度以导致髋部接触力穿过髋臼组件边缘的方式改变时,就会发生边缘载荷。边缘载荷使接触应力至少增加了50%;最大增长为108%。血清金属离子水平较低的患者在步态或下降过程中峰值力时接触压力没有增加。血清金属离子水平高的患者表现出边缘负荷,其髋臼组件的倾斜角增加。导致这些对象边缘负荷的倾斜角度的增加小于已发表的髋部接触力角度的受试者间差异。这项研究的结果表明,较高的血清金属离子水平是倾斜角影响边缘载荷的结果,但是边缘载荷不能仅归因于倾斜角,而且个人的活动方式可以减少甚至抵消陡峭的影响髋臼组件并防止边缘加载。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号