PURPOSE: Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or "lung mask," of a previous radiographic image to align with the current image. The gray levels of every pixel in the current image are subtracted from the gray levels of the corresponding pixels in the warped previous image to form a temporal subtraction image. While temporal subtraction images effectively enhance areas of pathologic change, misregistration of the images can mislead radiologists by obscuring the interval change or by creating artifacts that mimic change. The purpose of this study was to investigate the utility of mutual information computed between two registered radiographic chest images as a metric for distinguishing between clinically acceptable and clinically unacceptable temporal subtraction images. METHODS: A radiologist subjectively rated the image quality of 138 temporal subtraction images using a 1 (poor) to 5 (excellent) scale. To objectively assess the registration accuracy depicted in the temporal subtraction images, which is the main factor that affects the quality of these images, mutual information was computed on the two constituent registered images prior to their subtraction to generate a temporal subtraction image. Mutual information measures the joint entropy of the current image and the warped previous image, yielding a higher value when the gray levels of spatially matched pixels in each image are consistent. Mutual information values were correlated with the radiologist's subjective ratings. To improve this correlation, mutual information was computed from a spatially limited lung mask, which was cropped from the bottom by 10%-60%. Additionally, the number of gray-level values used in the joint entropy histogram was varied. The ability of mutual information to predict the clinical acceptability of a temporal subtraction image was evaluated through receiver operating characteristic (ROC) analysis. RESULTS: The mean correlation coefficient obtained between mutual information computed on constituent images and the subjective rating of temporal subtraction image quality was 0.785. ROC analysis yielded an average Az value of 0.852 for the ability of mutual information to distinguish between temporal subtraction images of clinically acceptable and clinically unacceptable quality. CONCLUSIONS: The results of this study establish a relationship between mutual information and temporal subtraction registration accuracy and demonstrate the ability of mutual information to objectively indicate the presence of misregistration artifacts.
机译:目的:颞叶相减用于检测胸部X线照片的间隔变化,并帮助放射科医生进行患者诊断。该方法通过几何变形前一幅放射照像图像的肺区域或“肺部遮罩”以与当前图像对齐,从而记录两个时间上不同的图像。从变形的先前图像中的相应像素的灰度级中减去当前图像中每个像素的灰度级,以形成时间相减图像。尽管时间相减图像有效地增强了病理变化的区域,但是图像的配准错误会掩盖间隔变化或产生模仿变化的伪像,从而误导放射线医师。这项研究的目的是调查在两个已注册的放射摄影胸部图像之间计算出的相互信息的实用性,以此作为区分临床上可接受的和临床上不可接受的时间减影图像的指标。方法:放射科医生使用1(较差)至5(优异)的比例对138个时间减影图像的主观质量进行了评级。为了客观地评估时间减影图像中描述的配准精度,这是影响这些图像质量的主要因素,在两个组成的配准图像相减之前计算互信息,以生成时间减影图像。互信息可测量当前图像和变形的先前图像的联合熵,当每个图像中空间匹配的像素的灰度级一致时,将产生较高的值。相互信息值与放射科医生的主观评分相关。为了改善这种相关性,从空间受限的肺罩中计算出相互信息,该肺罩从底部裁剪了10%-60%。此外,在联合熵直方图中使用的灰度值的数量也有所变化。通过接收器工作特征(ROC)分析评估了互信息预测时间相减图像的临床可接受性的能力。结果:在组成图像上计算的互信息与时间相减图像质量的主观评分之间的平均相关系数为0.785。 ROC分析得出的平均Az值为0.852,这是因为互信息具有区分临床上可接受的质量和临床上无法接受的质量的时间相减图像的能力。结论:这项研究的结果建立了相互信息和时间相减配准准确性之间的关系,并证明了相互信息能够客观地表明配准伪影的存在。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号