Good clinical physics practice requires that dose rates of brachytherapy sources be checked by the institution using them, as recommended by American Association of Physicists in Medicine Task Group 56 and The American College of Radiology. For intravascular brachytherapy with catheter-based systems, AAPM Task Group 60 recommends that the dose rate be measured at a reference point located at a radial distance of 2 mm from the center of the catheter axis. AAPM Task Group 60 also recommends that the dose rate along the catheter axis at a radial distance of 2 mm should be uniform to within +/- 10% in the center two-thirds of the treated length, and the relative dose rate in the plane perpendicular to the catheter axis through the center of the source should be measured at distances from 0.5 mm to R90 (the distance from a point source within which 90% of the energy is deposited) at intervals of 0.5 mm. Radiochromic film dosimetry has been used to measure the dose distribution in a plane parallel to and at a radial distance of 2 mm from the axis of a novel, catheter-based, beta source for intravascular brachytherapy. The dose rate was averaged along a line parallel to the catheter axis at a radial distance of 2 mm, in the centered 24.5 mm of the treated length. This average dose rate agreed with the dose rate measured with a well ionization chamber by the replacement method using source trains calibrated with an extrapolation chamber at the National Institute of Standards and Technology. All of the dose rates in the centered 24.5 mm of a line parallel to the axis at a distance of 2 mm were within +/-10% of the average.
机译:良好的临床物理学实践要求,按照美国医学物理学家协会任务组56和美国放射学院的建议,使用它们的机构应检查近距离放射源的剂量率。对于基于导管系统的血管内近距离放射治疗,AAPM任务组60建议在距导管轴中心2 mm的径向距离处的参考点测量剂量率。 AAPM任务组60还建议,在径向距离2 mm处沿导管轴线的剂量率应在治疗长度的三分之二的中心均匀地保持在+/- 10%以内,并且在平面上的相对剂量率垂直于穿过源中心的导管轴线的距离应在0.5 mm至R90的距离(距点源的距离,其中沉积90%的能量的距离)以0.5 mm的距离进行测量。放射致变色膜剂量测定法已被用于测量平行于平面的平面分布的剂量分布,该平面距新型的基于导管的,用于血管内近距离放射治疗的β轴的径向距离为2 mm。在治疗长度的中心24.5 mm处,沿平行于导管轴的线以2 mm的径向距离取平均剂量率。该平均剂量率与采用美国国家标准技术研究院外推法校准的源列的替换方法,在井电离室通过替代方法测得的剂量率一致。平行于轴的直线的中心24.5 mm中距离2 mm的所有剂量率均在平均值的+/- 10%之内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号