This work reports the transfer of the primary standard for air kerma from the National Institute of Standards and Technology (NIST) to the secondary laboratories accredited by the American Association of Physics in Medicine (AAPM). This transfer, performed in August of 2003, was motivated by the recent revision of the NIST air-kerma standards for 60Co gamma-ray beams implemented on July 1, 2003. The revision involved a complete recharacterization of the two NIST therapy-level 60Co gamma-ray beam facilities, resulting in new values for the air-kerma rates disseminated by the NIST. Some of the experimental aspects of the determination of the new air-kerma rates are briefly summarized here; the theoretical aspects have been described in detail by Seltzer and Bergstrom ["Changes in the U.S. primary standards for the air-kerma from gamma-ray beams," J. Res. Natl. Inst. Stand. Technol. 108, 359-381 (2003)]. The standard was transferred to reference-class chambers submitted by each of the AAPM Accredited Dosimetry Calibration Laboratories (ADCLs). These secondary-standard instruments were then used to characterize the 60Co gamma-ray beams at the ADCLs. The values of the response (calibration coefficient) of the ADCL secondary-standard ionization chambers are reported and compared to values obtained prior to the change in the NIST air-kerma standards announced on July 1, 2003. The relative change is about 1.1% for all of these chambers, and this value agrees well with the expected change in chambers calibrated at the NIST or at any secondary-standard laboratory traceable to the new NIST standard.
机译:这项工作报告了空气比释动能的主要标准已从美国国家标准技术研究院(NIST)转移到美国医学物理学会(AAPM)认可的二级实验室。这项转换是在2003年8月进行的,其动机是最近对2003年7月1日实施的60Co伽玛射线束的NIST空气比释动能标准进行了修订。该修订涉及两个NIST治疗级别的60Coγ的完全重新定性射线束设备,从而为NIST传播的空气比释动能值创造了新的价值。这里简要总结了确定新的空气比释动能速率的一些实验方面。理论方面已由Seltzer和Bergstrom详细描述过[“来自伽马射线束的空气比释动能的美国主要标准的变化,” J.Res.Chem。 Natl。研究所站。技术。 108,359-381(2003)]。该标准已转移到由AAPM认可的剂量学校准实验室(ADCL)提交的参考级试验箱中。这些次级标准仪器随后用于表征ADCL处的60Co伽马射线束。报告ADCL二级标准电离室的响应值(校准系数),并将其与在2003年7月1日宣布更改NIST空气比释动能标准之前获得的值进行比较。相对变化约为1.1%。所有这些小室,此值与在NIST或可追溯到新NIST标准的任何二级标准实验室校准的小室的预期变化非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号