PURPOSE: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. METHODS: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). RESULTS: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependence for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. CONCLUSIONS: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.
机译:目的:本文的目的是研究用平板扫描仪进行扫描以读取胶片时,放射性变色胶片类型Gafchromic EBT-1的能量依赖性。方法:确定了从10 kVp X射线束到15 MVp X射线束的12种不同束质量的剂量响应曲线,还包括两种高能电子束质量(6和18 MeV)。将针对不同光束质量的以净光密度(netOD)测量的剂量响应归一化为参考光束质量(6 MVp)的响应。结果:发现膜响应强烈的系统能量依赖性。有效光束能量越低,EBT-1膜的灵敏度越低。对于25 kVp和6 MVp光束质量之间相同的薄膜响应,最大剂量减少为44%。此外,还发现了不同剂量对能量的依赖性不同,这意味着与较低剂量相比,较高剂量对能量的依赖性较小。发现相对于10 Gy的归一化netOD,剂量为0.5 Gy的归一化netOD的最大降低为25%。此外,引入了定标程序,从而可以针对所研究的光束质量以及在所研究的能量范围内的可比较的X射线光束质量校正能量依赖性。结论:发现对EBT-1射线变色膜具有很强的能量依赖性。用平板扫描仪读出胶片。如果已知有效束能量,则可以通过引入的缩放过程来校正能量依赖性。需要进一步研究读出设备的光谱带对能量依赖性的影响,以了解在本工作和以前的工作中发现不同的能量依赖性的原因。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号