首页> 外文期刊>Medical Physics >Influence of x-ray pulse parameters on the image quality for moving objects in digital cardiac imaging.
【24h】

Influence of x-ray pulse parameters on the image quality for moving objects in digital cardiac imaging.

机译:X射线脉冲参数对数字心脏成像中运动物体的图像质量的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

The image quality of a single frame in a modern cardiac imaging x-ray facility can be improved by adjusting the automatic pulse exposure parameters. The effects of acquisition rate on patient dose and the detectability of moving objects have been fully described in scientific literature. However, the influence of automatic pulse exposure parameters is still to be determined. Images of a moving wheel (with lead wires) were acquired using an H5000 Philips Integris cardiac x-ray system. Poly(methylmethacrylate) plastic samples 20 and 30 cm thick were employed as the build-up phantom to simulate a patient. The images were obtained using preset clinical parameters for cardiac imaging procedures. The signal detectability and motion blur of a contrast bar at a transversal speed in the range of 100-150 mm/s were evaluated with a cine pulse width of 3, 5, 7, and 10 ms under automatic mA kV regulation. Two levels of exposure at the image intensifier entrance were included in this study. Signal detectability was analyzed in terms of the signal-to-noise ratio (SNR) and the value of SNR2/entrance surface dose. The blurring was modeled as a Gaussian-shaped blurring function, and the motion blur was expressed in terms of the peak full width at half maximum and amplitude (apparent contrast) of the resolution functions. A contrast bar simulating a vessel in motion at the maximum velocities of typical cardiac structures was exposed. Severe loss of image quality occurred at pulse widths > or =7 ms. It is also shown that below 5 ms static nonlinearities, likely caused by the need to use a large focus for cine acquisition, dominate the blurring process.
机译:通过调整自动脉冲曝光参数,可以改善现代心脏成像X射线设备中单帧的图像质量。科学文献中已充分描述了采集速率对患者剂量和移动物体可检测性的影响。但是,自动脉冲曝光参数的影响仍有待确定。使用H5000 Philips Integris心脏X射线系统获取了动轮(带有导线)的图像。使用20厘米和30厘米厚的聚甲基丙烯酸甲酯塑料样品作为模拟人体的模型。使用用于心脏成像程序的预设临床参数获得图像。在自动mA kV调节下,以3、5、7和10 ms的电影脉冲宽度评估在100-150 mm / s范围内的横向速度下对比度条的信号可检测性和运动模糊。这项研究包括图像增强器入口处的两个曝光水平。根据信噪比(SNR)和SNR2 /入口表面剂量的值分析了信号的可检测性。将模糊建模为高斯形状的模糊函数,并以最大半峰宽和分辨率函数的振幅(表观对比度)表示运动模糊。暴露了以典型心脏结构的最大速度模拟运动中的血管的对比杆。脉冲宽度>或= 7 ms时,图像质量严重下降。还表明,在5 ms以下,静态非线性可能是由模糊处理引起的,该静态非线性可能是由于需要使用较大的聚焦来获取电影而引起的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号