PURPOSE: Implanted markers are commonly used in radiotherapy for x-ray based target localization. The projected marker position in a series of cone-beam CT (CBCT) projections can be used to estimate the three dimensional (3D) target trajectory during the CBCT acquisition. This has important applications in tumor motion management such as motion inclusive, gating, and tumor tracking strategies. However, for irregularly shaped markers, reliable segmentation is challenged by large variations in the marker shape with projection angle. The purpose of this study was to develop a semiautomated method for robust and reliable segmentation of arbitrarily shaped radiopaque markers in CBCT projections. METHODS: The segmentation method involved the following three steps: (1) Threshold based segmentation of the marker in three to six selected projections with large angular separation, good marker contrast, and uniform background; (2) construction of a 3D marker model by coalignment and backprojection of the threshold-based segmentations; and (3) construction of marker templates at all imaging angles by projection of the 3D model and use of these templates for template-based segmentation. The versatility of the segmentation method was demonstrated by segmentation of the following structures in the projections from two clinical CBCT scans: (1) Three linear fiducial markers (Visicoil) implanted in or near a lung tumor and (2) an artificial cardiac valve in a lung cancer patient. RESULTS: Automatic marker segmentation was obtained in more than 99.9% of the cases. The segmentation failed in a few cases where the marker was either close to a structure of similar appearance or hidden behind a dense structure (data cable). CONCLUSIONS: A robust template-based method for segmentation of arbitrarily shaped radiopaque markers in CBCT projections was developed.
机译:目的:植入的标记物通常在放射治疗中用于基于X射线的靶标定位。一系列锥形束CT(CBCT)投影中的投影标记位置可用于估计CBCT采集过程中的三维(3D)目标轨迹。这在肿瘤运动管理中具有重要的应用,例如运动包含,门控和肿瘤跟踪策略。然而,对于形状不规则的标记,可靠的分割受到标记形状随投影角度的大变化的挑战。这项研究的目的是开发一种半自动方法,用于对CBCT投影中的任意形状的不透射线标记物进行可靠且可靠的分割。方法:分割方法包括以下三个步骤:(1)基于阈值的三到六个选定投影的标记分割,这些投影具有大的角度间隔,良好的标记对比度和均匀的背景; (2)通过基于阈值的分割的共对齐和反投影来构建3D标记模型; (3)通过投影3D模型并在所有成像角度构建标记模板,并将这些模板用于基于模板的分割。通过两次临床CBCT扫描的投影中的以下结构的分割,证明了分割方法的多功能性:(1)三种线性基准标记(Visicoil)植入肺肿瘤内或附近,以及(2)人工心脏瓣膜肺癌患者。结果:99.9%以上的病例获得了自动标记分割。在少数情况下,如果标记靠近相似外观的结构或隐藏在密集结构(数据电缆)后面,则分割失败。结论:建立了基于鲁棒的基于模板的CBCT投影中任意形状的不透射线标记分割方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号