首页> 外文期刊>Free Radical Biology and Medicine: The Official Journal of the Oxygen Society >Urinary analysis of 8-oxo-7,8-dihydroguanine and 8-oxo-7,8-dihydro-2'-deoxyguanosine by isotope-dilution LC-MS/MS with automated solid-phase extraction: Study of 8-oxo-7,8-dihydroguanine stability.
【24h】

Urinary analysis of 8-oxo-7,8-dihydroguanine and 8-oxo-7,8-dihydro-2'-deoxyguanosine by isotope-dilution LC-MS/MS with automated solid-phase extraction: Study of 8-oxo-7,8-dihydroguanine stability.

机译:同位素稀释LC-MS / MS自动固相萃取分析尿中的8-oxo-7,8-8,dihydroguanine和8-oxo-7,8-dihydro-2'-deoxyguanosine:8-oxo-7的研究,8-二氢鸟嘌呤稳定。

获取原文
获取原文并翻译 | 示例
           

摘要

A highly sensitive quantitative method based on LC-MS/MS was developed to simultaneously and directly measure 8-oxo-7,8-dihydroguanine (8-oxoGua) and 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) in urine. It was found that 8-oxoGua could be artifactually generated from 8-oxodGuo during the ionization process by both in-source thermolysis and collisionally induced dissociation. Our method applied a two-stage wash procedure in the online solid-phase extraction system that not only eliminated ion suppression but also prevented artifactual interference with 8-oxoGua by 8-oxodGuo by eluting the analytes individually. With the use of isotope internal standards, the detection limits of 8-oxoGua and 8-oxodGuo were estimated to be 30 and 3.5 fmol, respectively. The 8-oxoGua stability under common storage conditions was first investigated. Dissolved 8-oxoGua in NaOH (pH 12) was quite fragile and stable for only <1 day at room temperature. When pH and temperature were reduced, the 8-oxoGua stability at -20 degrees C was significantly increased to approximately 87 days in water (pH approximately 7) and approximately 112 days when diluted in 5% methanol. This method was further applied to measure urinary samples of healthy subjects. A molar ratio of 8-oxoGua to 8-oxodGuo of approximately 4.6 was found, supporting the hypothesis that oxidatively damaged DNA is primarily repaired by the base excision repair pathway.
机译:开发了一种基于LC-MS / MS的高灵敏度定量方法,可同时直接测量8-oxo-7,8-dihydroguanine(8-oxoGua)和8-oxo-7,8-dihydro-2'-deoxyguanosine(8 -oxodGuo)。已发现,在离子化过程中,通过源内热解和碰撞诱导解离,可以从8-oxodGuo人为地生成8-oxoGua。我们的方法在在线固相萃取系统中应用了两步洗涤程序,该程序不仅消除了离子抑制作用,而且还通过分别洗脱分析物而防止了8-oxodGuo对8-oxoGua的人为干扰。使用同位素内标,估计8-oxoGua和8-oxodGuo的检出限分别为30和3.5 fmol。首先研究了在普通储存条件下的8-oxoGua稳定性。在NaOH(pH 12)中溶解的8-oxoGua相当脆弱,并且在室温下仅稳定<1天。当降低pH和温度时,在-20℃下的8-oxoGua稳定性在水中(pH约为7)显着增加到大约87天,而在5%甲醇中稀释则大约112天。该方法进一步应用于测量健康受试者的尿液样本。发现8-oxoGua与8-oxodGuo的摩尔比约为4.6,这支持了氧化损伤的DNA主要通过碱基切除修复途径修复的假说。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号