首页> 外文期刊>Free Radical Biology and Medicine: The Official Journal of the Oxygen Society >Decreased sensitivity associated with an altered formulation of a commercially available kit for detection of protein carbonyls.
【24h】

Decreased sensitivity associated with an altered formulation of a commercially available kit for detection of protein carbonyls.

机译:与用于检测蛋白质羰基的市售试剂盒的配方变更相关的灵敏度降低。

获取原文
获取原文并翻译 | 示例
           

摘要

Carbonylation is a commonly studied form of oxidative modification to proteins which can be conveniently detected using commercially available kits. The most common of these kits is the Oxyblot Protein Oxidation Detection Kit (Chemicon/Millipore). Over the past year we have observed severely diminished sensitivity of these kits which was shown to be a result of a change in the formulation of one of the components supplied in the kit. This component, the 10X 2,4-dinitrophenylhydrazine derivatization solution, which had previously been dissolved in 100% trifluoroacetic acid (TFA), was now dissolved in 2N hydrochloric acid, which according to our results is not acid enough. Further, we observed that upon storage even DNPH dissolved in TFA is subject to degradation. Based on these studies, we make recomendations that should improve the sensitivity and reproducibilty of this assay.
机译:羰基化是蛋白质氧化修饰的一种常用研究形式,可以使用市售试剂盒方便地检测到。这些试剂盒中最常见的是Oxyblot蛋白质氧化检测试剂盒(Chemicon / Millipore)。在过去的一年中,我们观察到这些试剂盒的灵敏度大大降低,这是由于试剂盒中提供的一种成分的配方发生了变化。该组分10X 2,4-二硝基苯肼衍生化溶液以前溶解在100%三氟乙酸(TFA)中,现在溶解在2N盐酸中,根据我们的结果,该酸不够酸。此外,我们观察到在储存时,甚至溶解在TFA中的DNPH也会降解。基于这些研究,我们提出了建议,可以提高该测定的灵敏度和可重复性。