Analysis of the ST-T complex of the electrocardiogram using the Karhunen--Loeve transform: adaptive monitoring and alternans detection.

机译:使用Karhunen-Loeve变换分析心电图的ST-T复杂度:自适应监测和交替检测。

获取原文
获取原文并翻译 | 示例
           

摘要

The Karhunen-Loeve transform (KLT) is applied to study the ventricular repolarisation period as reflected in the ST-T complex of the surface ECG. The KLT coefficients provide a sensitive means of quantitating ST-T shapes. A training set of ST-T complexes is used to derive a set of KLT basis vectors that permits representation of 90% of the signal energy using four KLT coefficients. As a truncated KLT expansion tends to favor representation of the signal over any additive noise, a time series of KLT coefficients obtained from successive ST-T complexes is better suited for representation of both medium-term variations (such as ischemic changes) and short-term variations (such as ST-T alternans) than discrete parameters such as the ST level or other local indices. For analysis of ischemic changes, an adaptive filter is described that can be used to estimate the KLT coefficient, yielding an increase in the signal-to-noise ratio of 10 dB (u = 0.1), with a convergence time of about three beats. A beat spectrum of the unfiltered KLT coefficient series is used for detection of ST-T alterans. These methods are illustrated with examples from the European ST-T Database. About 20% of records revealed quasi-periodic salvos of ischemic ST-T change episodes and another 20% exhibit repetitive, but not clearly periodic patterns of ST-T change episodes. About 5% of ischemic episodes were associated with ST-T alterans.
机译:Karhunen-Loeve变换(KLT)用于研究表面ECG的ST-T复合体中反映的心室复极化期。 KLT系数提供了量化ST-T形状的灵敏手段。 ST-T复数的训练集用于导出一组KLT基向量,该向量允许使用四个KLT系数表示90%的信号能量。由于截断的KLT扩展倾向于倾向于表示信号而不是任何附加噪声,因此从连续的ST-T络合物获得的KLT系数的时间序列更适合于表示中期变化(例如缺血性变化)和短期变化。术语变化(例如ST-T交替词),而不是离散参数(例如ST级别或其他本地索引)。为了分析缺血性变化,描述了一种自适应滤波器,该滤波器可用于估计KLT系数,从而使信噪比增加10 dB(u = 0.1),收敛时间约为3次。未过滤的KLT系数系列的拍频谱用于检测ST-T交流发电机。通过欧洲ST-T数据库的示例说明了这些方法。大约20%的记录显示出缺血性ST-T改变发作的准周期性齐射,另外20%的记录显示出ST-T改变发作的重复但不是周期性的模式。约5%的缺血性发作与ST-T交替肌有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号