This work presents a study on the influence of the aqueous environment on the surface EMG (sEMG) signal recorded in bipolar montage from the abductor pollicis brevis muscle, when only the forearm is immersed in water. Ten men, 30.1+/-4.0 (mean +/- SD) years old, performed ten 2-s 40% MVC isometric contractions of the abductor pollicis brevis muscle in two controlled environments (air and water, at a temperature of 32 degrees C). They were always equipped with electrodes protected with a waterproof adhesive tape. No significant variations (paired Wilcoxon test) due to the environments were observed in the median frequency of the power spectrum (MDF) and in the root mean square (RMS) value of the sEMG signal. These results allow us to assess the methodological criteria to properly record sEMG signals in water and provide the basis to explain different findings obtained by other authors.
机译:这项工作提出了一项研究,即当仅将前臂浸入水中时,水环境对外展短腿外展肌的双极蒙太奇记录的表面EMG(sEMG)信号的影响。 10名30.1 +/- 4.0(平均+/- SD)岁的男人在两个受控环境(空气和水)中,在32摄氏度的温度下,对外展肌短肌外展肌进行了10次2-s 40%MVC等距收缩)。它们始终配备有用防水胶带保护的电极。在功率谱(MDF)的中值频率和sEMG信号的均方根(RMS)值方面,未观察到因环境引起的显着变化(成对的Wilcoxon测试)。这些结果使我们能够评估正确记录水中sEMG信号的方法学标准,并为解释其他作者获得的不同发现提供基础。