首页> 外文期刊>Medical and Biological Engineering and Computing: Journal of the International Federation for Medical and Biological Engineering >3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC((R)) system.
【24h】

3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC((R)) system.

机译:在ORTHODOC(R)系统中基于股骨后平面的3D股骨颈前倾测量。

获取原文
获取原文并翻译 | 示例
           

摘要

This study provides a robust measuring method of the femoral neck anteversion angle for use in a total hip replacement pre-planning program. The femora of 24 patients (69.3 +/- 6.3 years old) were CT-scanned and converted into three-dimensionally volume-rendered models in ORTHODOC((R) )(ISS Inc., CA, USA) which is the pre-planning software for ROBODOC surgery. The Mod.ISS method (the modified ISS method), designed by authors, measures the anteversion angle of the proximal-most femoral neck confluence on the plane perpendicular to the femoral mechanical axis. 3D FNC method proposed by the authors of the present study involves measurement of the anteversion angle of three-dimensional femoral neck center on a plane perpendicular to the posterior femoral plane and parallel to the posterior condylar axis. Here, we found that interobserver reproducibility was 1.8 degrees (SD = 1.3) for the Mod.ISS method and 2.4 (SD = 1.9) for the proposed 3D FNC method. The anteversion angle of the local femoral neck axis was measured as theta = 25.3(L/D) - 5.4 in L/D = 0.1 approximately 0.6, where L/D is distance (L) from the proximal-most neck confluence along the femoral mechanical axis, normalized with respect to the diameter of the femoral head (D). At L/D = 0.5, the anteversion angle of the femoral neck axis was coincident with the average femoral neck anteversion determined by the 3D FNC method. We conclude that the 3D FNC method is a gold standard for measuring the femoral neck anteversion applicable during both pre-operative and post-operative stages, because its femoral neck center can be determined in three-dimensional space during both stages.
机译:这项研究为整个髋关节置换预计划中使用的股骨颈前倾角提供了一种可靠的测量方法。在预先计划的ORTHODOC(R)(ISS Inc.,CA,USA)中,对24例患者(69.3 +/- 6.3岁)的股骨进行了CT扫描并将其转换为三维体积渲染模型。 ROBODOC手术软件。作者设计的Mod.ISS方法(改进的ISS方法)测量垂直于股骨机械轴的平面上最近端股骨颈融合的前倾角。本研究的作者提出的3D FNC方法涉及在垂直于股骨后平面并平行于con后轴的平面上测量三维股骨颈中心的前倾角。在这里,我们发现对于Mod.ISS方法,观察者之间的可重复性为1.8度(SD = 1.3),对于建议的3D FNC方法,观察者之间的可重复性为2.4度(SD = 1.9)。局部股骨颈轴的前倾角为theta = 25.3(L / D)-5.4,L / D = 0.1约为0.6,其中L / D是沿股骨距最近颈融合处的距离(L)机械轴,相对于股骨头直径(D)进行标准化。在L / D = 0.5时,股骨颈轴的前倾角与通过3D FNC方法确定的平均股骨颈前倾一致。我们得出的结论是,3D FNC方法是测量股骨颈前倾的金标准,适用于术前和术后阶段,因为其股骨颈中心可在两个阶段的三维空间中确定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号