Skin doses have been an important factor in the dose prescription for breast radiotherapy. Recent advances in radiotherapy treatment techniques, such as intensity-modulated radiation therapy (IMRT) and new treatment schemes such as hypofractionated breast therapy have made the precise determination of the surface dose necessary. Detailed information of the dose at various depths of the skin is also critical in designing new treatment strategies. The purpose of this work was to assess the accuracy of surface dose calculation by a clinically used treatment planning system and those measured by thermoluminescence dosimeters (TLDs) in a customized chest wall phantom. This study involved the construction of a chest wall phantom for skin dose assessment. Seven TLDs were distributed throughout each right chest wall phantom to give adequate representation of measured radiation doses. Point doses from the CMS Xio? treatment planning system (TPS) were calculated for each relevant TLD positions and results correlated. There were no significant difference between measured absorbed dose by TLD and calculated doses by the TPS (. p > 0.05 (1-tailed). Dose accuracy of up to 2.21% was found. The deviations from the calculated absorbed doses were overall larger (3.4%) when wedges and bolus were used. 3D radiotherapy TPS is a useful and accurate tool to assess the accuracy of surface dose. Our studies have shown that radiation treatment accuracy expressed as a comparison between calculated doses (by TPS) and measured doses (by TLD dosimetry) can be accurately predicted for tangential treatment of the chest wall after mastectomy.
机译:皮肤剂量已成为乳腺癌放射治疗剂量处方中的重要因素。放射治疗技术的最新进展,例如强度调制放射治疗(IMRT),以及新的治疗方案,例如超分割的乳房治疗,使得精确确定表面剂量成为必要。在设计新的治疗策略时,在皮肤各个深度处的剂量的详细信息也至关重要。这项工作的目的是通过临床使用的治疗计划系统评估表面剂量计算的准确性,并通过定制的胸壁体模中的热致发光剂量计(TLD)来评估表面剂量。该研究涉及用于皮肤剂量评估的胸壁幻影的构建。在每个右胸壁体模中分布了七个TLD,以充分表示测量的辐射剂量。来自CMS Xio的点剂量?针对每个相关TLD职位计算出治疗计划系统(TPS),并将结果关联起来。 TLD测得的吸收剂量与TPS测得的剂量之间无显着差异(。p> 0.05(1尾)。发现剂量准确度高达2.21%。与计算出的吸收剂量的偏差总体上更大(3.4)。 3D放射治疗TPS是评估表面剂量准确性的有用且准确的工具,我们的研究表明,放射治疗的准确性表示为计算剂量(通过TPS)和测量剂量(通过TLD剂量法可以准确预测乳房切除术后胸壁的切向治疗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号