Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

机译:鼻咽癌体外放疗中束流布置对口腔剂量的影响

获取原文
获取原文并翻译 | 示例
       

摘要

This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.
机译:这项研究比较了常规7束强度调制放射治疗(IMRT)光束布置与其他2根7束IMRT与常规放射治疗光束布置在鼻咽癌(NPC)治疗中的口腔剂量。招募了2009年4月至2009年6月之间用7束常规IMRT技术(IMRT-7R)治疗的10名NPC患者。使用相同的计算机断层扫描数据,目标信息以及所有轮廓结构的剂量限制,通过避免前束束的2种IMRT计划和其他束安排(IMRT-7M和IMRT-7P)和1项常规放射治疗计划(CONRT)使用Pinnacle治疗计划系统进行计算。生成了计划目标体积(PTV)和口腔的剂量体积直方图,从中记录了剂量参数和PTV的合格指数,用于在不同光束布置的计划之间进行剂量比较。在3个IMRT光束装置中,PTV的剂量分布相似,而IMRT-7R和CONRT计划之间的差异却很大。对于口腔剂量,3个IMRT光束排列没有显示明显差异。与IMRT-7R相比,CONRT计划显示平均剂量V30和V-40显着降低,而V-60明显更高。 2建议的替代束安排并没有显着减少口腔剂量。 NPC的IMRT中改变光束角度的影响对目标和口腔没有明显的影响。与IMRT相比,传统的2D放射疗法在口腔中的照射剂量更大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号