Effect of image value-to-density table (IVDT) on the accuracy of delivery quality assurance (DQA) process in helical tomotherapy

机译:图像值密度表(IVDT)对螺旋断层扫描中的交付质量保证(DQA)过程准确性的影响

获取原文
获取原文并翻译 | 示例
       

摘要

The effect of the accuracy in the application of the image value-to-density table (IVDT) from kilovoltage computed tomography (kVCT) and mega-voltage computed tomography (MVCT) images on the delivery quality assurance (DQA) in helical tomotherapy (HT) was analyzed. The DQA plans were prepared with a kVCT image of a cheese phantom for 10 HT patients, and the difference in absolute dose equivalence between the planned and real measurement was evaluated according to the accuracy of IVDT application. The difference between the calculated dose distribution and real dose distribution measured with MapCHECK (SunNuclear, Melbourne, FL) was analyzed through the DQA process with a kVCT MapCHECK image and the same analysis was performed with an MVCT MapCHECK image. The IVDT for kVCT was applied to MVCT and the variation in error between the planned and real measurement caused by improper application of IVDT was evaluated. The accuracy of the IVDT application in the homogeneous water-equivalent cheese phantom had only a minor influence on the dose calculation. Although the overall accuracy of the calculated dose was increased when the proper IVDT was applied, this result had no statistical significance. The MVCT image of MapCHECK contained less error between the calculated dose and delivered dose with a high pass rate. The proper IVDT application to the MVCT image of MapCHECK increased the accuracy of dose calculation, and this result had a statistical significance. Application of the correct IVDT is important in HT DQA and its significance is increased when using phantoms consisting of inhomogeneous density materials.
机译:千伏计算机断层扫描(kVCT)和兆伏计算机断层扫描(MVCT)图像的图像密度比表(IVDT)的应用精度对螺旋断层扫描(HT)的输送质量保证(DQA)的影响)进行了分析。为DQA计划准备了10例HT患者的奶酪模型的kVCT图像,并根据IVDT应用的准确性评估了计划和实际测量之间的绝对剂量当量差异。通过kVCT MapCHECK图像通过DQA处理分析了用MapCHECK(SunNuclear,墨尔本,佛罗里达州)测量的剂量分布与实际剂量分布之间的差异,并使用MVCT MapCHECK图像进行了相同的分析。将kVCT的IVDT应用于MVCT,并评估了由于IVDT的不正确使用而导致的计划和实际测量之间的误差变化。在均质的水当量奶酪模型中,IVDT应用的准确性对剂量计算影响很小。尽管使用适当的IVDT可以提高计算剂量的总体准确性,但该结果没有统计学意义。 MapCHECK的MVCT图像在计算出的剂量和输送的剂量之间具有较高的合格率,误差较小。将适当的IVDT应用于MapCHECK的MVCT图像可提高剂量计算的准确性,这一结果具有统计学意义。正确的IVDT的应用在HT DQA中很重要,当使用由不均匀密度材料组成的幻象时,其重要性会增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号