首页> 外文期刊>Medical dosimetry: official journal of the American Association of Medical Dosimetrists >Factors affecting prostate volume estimation in computed tomography images.
【24h】

Factors affecting prostate volume estimation in computed tomography images.

机译:影响计算机断层扫描图像中前列腺体积估计的因素。

获取原文
获取原文并翻译 | 示例
       

摘要

The aim of this study was to investigate how apex-localizing methods and the computed tomography (CT) slice thickness affected the CT-based prostate volume estimation. Twenty-eight volunteers underwent evaluations of prostate volume by CT, where the contour segmentations were performed by three observers. The bottom of ischial tuberosities (ITs) and the bulb of the penis were used as reference positions to locate the apex, and the distances to the apex were recorded as 1.3 and 2.0 cm, respectively. Interobserver variations to locate ITs and the bulb of the penis were, on average, 0.10 cm (range 0.03-0.38 cm) and 0.30 cm (range 0.00-0.98 cm), respectively. The range of CT slice thickness varied from 0.08-0.48 cm and was adopted to examine the influence of the variation on volume estimation. The volume deviation from the reference case (0.08 cm), which increases in tandem with the slice thickness, was within +/- 3 cm(3), regardless of the adopted apex-locating reference positions. In addition, the maximum error of apex identification was 1.5 times of slice thickness. Finally, based on the precise CT films and the methods of apex identification, there were strong positive correlation coefficients for the estimated prostate volume by CT and the transabdominal ultrasonography, as found in the present study (r > 0.87; p < 0.0001), and this was confirmed by Bland-Altman analysis. These results will help to identify factors that affect prostate volume calculation and to contribute to the improved estimation of the prostate volume based on CT images.
机译:这项研究的目的是调查顶点定位方法和计算机断层扫描(CT)切片厚度如何影响基于CT的前列腺体积估计。 28名志愿者接受了CT评估的前列腺体积,其中由三名观察员进行了轮廓分割。坐骨结节(ITs)的底部和阴茎的球茎被用作定位顶点的参考位置,到顶点的距离分别记录为1.3和2.0 cm。观察者之间用于定位IT和阴茎球的变异平均分别为0.10 cm(范围0.03-0.38 cm)和0.30 cm(范围0.00-0.98 cm)。 CT切片厚度的范围从0.08-0.48 cm不等,并被用来检查变化对体积估计的影响。与参考案例的体积偏差(0.08 cm)随切片厚度的增加而增加,在+/- 3 cm(3)之内,与采用的顶点定位参考位置无关。另外,根尖识别的最大误差是切片厚度的1.5倍。最后,根据精确的CT胶片和先端识别方法,通过CT和经腹超声检查估计的前列腺体积具有很强的正相关系数,如本研究所述(r> 0.87; p <0.0001),并且这通过Bland-Altman分析得到了证实。这些结果将有助于识别影响前列腺体积计算的因素,并有助于基于CT图像改进前列腺体积的估计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号