首页> 外文期刊>Materials and Corrosion >Study of criterion for assuring the effectiveness of cathodic protection of buried steel pipelines being interfered with alternative current
【24h】

Study of criterion for assuring the effectiveness of cathodic protection of buried steel pipelines being interfered with alternative current

机译:确保埋地钢管受到交流干扰的阴极保护有效性的标准研究

获取原文
获取原文并翻译 | 示例
           

摘要

Interference of alternative current (AC) on corrosion of X65 steel was investigated in soil. It was observed that the unfavorable effect of interfering AC was able to be effectively inhibited by increasing the direct current density of the cathodic protection (CP) system. A clear correlation was established between the CP current density and the tolerable AC current density. This led to a new criterion for assuring the effectiveness of CP of buried pipelines being interfered with AC. Field experimental results on a buried pipeline running below a 500 kV transmission line showed that the criterion could satisfactorily predict the risk of AC interfering on the CP system.
机译:研究了交流电对土壤中X65钢腐蚀的影响。观察到,通过增加阴极保护(CP)系统的直流电流密度,可以有效地抑制交流干扰的不利影响。在CP电流密度和可容许的AC电流密度之间建立了明确的相关性。这导致了一个新标准,以确保地下管道的CP的有效性受到AC的干扰。在500 kV输电线路下运行的地下管道的现场实验结果表明,该标准可以令人满意地预测交流电对CP系统的干扰风险。