首页> 外文期刊>Canadian journal of gastroenterology >Hydrogen breath test for diagnosis of lactose malabsorption: the importance of timing and the number of breath samples.
【24h】

Hydrogen breath test for diagnosis of lactose malabsorption: the importance of timing and the number of breath samples.

机译:氢气呼气试验对乳糖吸收不良的诊断:计时的重要性和呼气样本的数量。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: The hydrogen breath test (H(2)BT) is the most widely used procedure in the diagnostic workup of lactose malabsorption and lactose intolerance. AIM: To establish whether a simplified two- or three-sample test may reduce time, costs and staff resources without reducing the sensitivity of the procedure. PATIENTS AND METHODS: Data from 1,112 patients (292 men, 820 women) with a positive 4 h, nine-sample H(2)BT were retrospectively analyzed. Patients were stratified according to the degree of lactose malabsorption, the occurrence and type of symptoms. Loss of sensitivity in the procedure was evaluated taking into account two-sample tests (0 min and 120 min or 0 min and 210 min) or three-sample tests (0 min, 120 min and 180 min or 0 min, 120 min and 210 min). RESULTS: Using a two-sample test (0 min and 120 min or 0 min and 210 min) the false-negative rate was 33.4% and 22.7%, respectively. With a three-sample test (0 min, 120 min and 180 min or 0 min, 120 min or 210 min), lactose malabsorption was diagnosed in 91.2% (1,014 of 1,112) patients and in 96.1% (1,068 of 1,112) patients, respectively. Of 594 patients with abdominal symptoms, 158 (26.6%) and 73 (12.2%) would have false-negative results with 0 min and 120 min or 0 min and 210 min two-sample tests, respectively. The three-sample tests, 0 min, 120 min and 180 min or 0 min, 120 min and 210 min, have a false-negative rate of 5.9% and 2.1%, respectively. CONCLUSIONS: A three-sample H(2)BT is time- and cost-sparing without significant loss of sensitivity for the diagnosis both of lactose malabsorption and lactose intolerance.
机译:背景:氢呼气试验(H(2)BT)是乳糖吸收不良和乳糖不耐症的诊断检查中使用最广泛的程序。目的:确定简化的两样本或三样本测试可以减少时间,成本和人力资源,同时又不降低程序的敏感性。病人和方法:回顾性分析了来自4例阳性4小时H(2)BT的1112例患者(292例男性,820例女性)的数据。根据乳糖吸收不良的程度,症状的发生和类型对患者进行分层。考虑到两个样品测试(0分钟和120分钟或0分钟和210分钟)或三个样品测试(0分钟,120分钟和180分钟或0分钟,120分钟和210个)来评估程序中的灵敏度损失分钟)。结果:使用两个样本的测试(0分钟和120分钟或0分钟和210分钟),假阴性率分别为33.4%和22.7%。通过三样本测试(0分钟,120分钟和180分钟或0分钟,120分钟或210分钟),在91.2%(1,112名中的1,014名)患者和96.1%(1,112名中的1,068名)患者中诊断为乳糖吸收不良,分别。在594例有腹部症状的患者中,分别进行0分钟和120分钟或0分钟和210分钟的两次抽样测试,分别有158(26.6%)和73(12.2%)的假阴性结果。这三个样本测试分别为0分钟,120分钟和180分钟,或0分钟,120分钟和210分钟,其假阴性率分别为5.9%和2.1%。结论:三样品H(2)BT是节省时间和成本,而对于乳糖吸收不良和乳糖不耐症的诊断都没有明显的敏感性损失。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号