首页> 外文期刊>Magnetic resonance in medicine: official journal of the Society of Magnetic Resonance in Medicine >Image restoration and spatial resolution in 7-tesla magnetic resonance imaging.
【24h】

Image restoration and spatial resolution in 7-tesla magnetic resonance imaging.

机译:7特斯拉磁共振成像中的图像恢复和空间分辨率。

获取原文
获取原文并翻译 | 示例
           

摘要

A good spatial resolution is essential for high precision segmentations of small structures in magnetic resonance images. However, any increase in the spatial resolution results in a decrease of the signal-to-noise ratio (SNR). In this article, this problem is addressed by a new image restoration technique that is used to partly compensate for the loss in SNR. Specifically, a two-stage hybrid image restoration procedure is proposed where the first stage is a Wiener wavelet filter for an initial denoising. The artifacts that will inevitably be produced by this step are subsequently reduced using a recent variant of anisotropic diffusion. The method is applied to magnetic resonance imaging data acquired on a 7-T magnetic resonance imaging scanner and compared with averaged multiple measurements of the same subject. It was found that the effect of image restoration procedure roughly corresponds to averaging across three repeated measurements.
机译:良好的空间分辨率对于磁共振图像中小结构的高精度分割至关重要。但是,空间分辨率的任何增加都会导致信噪比(SNR)降低。在本文中,此问题通过一种新的图像恢复技术解决,该技术用于部分补偿SNR的损失。具体地,提出了两阶段混合图像恢复过程,其中第一阶段是用于初始降噪的维纳小波滤波器。随后将使用各向异性扩散的最新变体来减少将不可避免地通过此步骤产生的伪影。该方法应用于在7-T磁共振成像扫描仪上采集的磁共振成像数据,并与同一受试者的平均多次测量结果进行比较。已经发现,图像恢复过程的效果大致对应于三个重复测量的平均值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号