PURPOSE: To observe the changes in permeability and elasticity in the cuff of the laryngeal mask airway (LMA) caused by repeated use. METHODS: In vitro use was simulated on six # 4 LMAs on 140 occasions. Ambient air was insufflated into the cuff until a value of 200 mmHg intracuff pressure (ICP) was reached, and this was maintained for 50 min. After each simulation, the LMA was sterilized at 121 degrees C for 20 min. After every 20 simulations insufflation of 40 ml air was carried out to determine the maximum value of ICP (initial ICP), and after three hours, spontaneous deflation (final ICP) was measured. The values of initial and final ICPs throughout the eight tests were attributed to the elastance and the permeability of the cuff respectively. At the end of the study the thickness of the wall of the cuffs was measured using an optical microscope. RESULTS: The initial ICP with the new LMA (first test) was of 191 +/- 4.4 mmHg. This value increased from the fifth test onwards until the end of the study. The value of the final ICP in the first test was 111 +/- 3 mmHg and decreased with successive sterilizations. Between 80 and 100 simulations, initial ICP increased from 186.5 +/- 2.9 to 191.7 +/- 2.3 (P = 0.006). The thickness of the wall (694 +/- 17 microns) was inversely related with the elasticity and the permeability of the cuff. CONCLUSIONS: The "safe" life-span of the cuff of the LMAs, measured by the initial modifications of the physical properties of the silicone during simulations, was estimated to be 80-100 uses and was related to the thickness of its wall.
机译:目的:观察反复使用引起的喉罩气道(LMA)袖带通透性和弹性的变化。方法:在140次场合下,在6个4号LMA上模拟了体外使用。将空气注入袖带中,直到达到200 mmHg袖带内压力(ICP)的值,并保持50分钟。每次模拟后,将LMA在121摄氏度下灭菌20分钟。每进行20次模拟后,进行40 ml空气吹入以确定ICP(初始ICP)的最大值,并在三小时后测量自发放气(最终ICP)。在整个八次测试中,初始和最终ICP的值分别归因于袖带的弹性和透气性。在研究结束时,使用光学显微镜测量袖带壁的厚度。结果:新的LMA(首次测试)的初始ICP为191 +/- 4.4 mmHg。该值从第五次测试开始直至研究结束。在第一次测试中,最终ICP的值为111 +/- 3 mmHg,并随着连续灭菌而降低。在80到100次仿真之间,初始ICP从186.5 +/- 2.9增加到191.7 +/- 2.3(P = 0.006)。壁的厚度(694 +/- 17微米)与袖带的弹性和渗透性成反比。结论:LMA袖带的“安全”寿命是通过模拟过程中硅酮物理性能的初步改变而测得的,估计使用了80-100次,并与其壁厚有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号