Full Paper: For the direct determination of axial dispersion in size exclusion chromatography a simple method is presented which makes use of the measured and ideal peak widths. The peak width can be defined in two ways: either absolute as the difference of successive points of inflection or relative as the ratio of these points. If the absolute peak width is invariant for the number, molar mass and hyper distribution then this distribution can unambiguously be classified as Poissonian. The relative peak width for such distributions is strictly determined by the experimental parameters. It is demonstrated that axial dispersion only leads to an additive increase in the peak variances for peaks with a relative peak width small than 1.25. thus, it is possible to determine directly the axial dispersion of an experimental size exclusion chromatography set-up by the use of Poisson distributions prepared by quenched instationary polymerization techniques or any other technique leading to ideal Poisson distributions. [References: 23]
机译:全文:为了直接测定尺寸排阻色谱法中的轴向分散度,提出了一种简单的方法,该方法利用了测得的峰宽和理想峰宽。峰宽可以通过两种方式定义:绝对值(即连续拐点的差)或相对值(即这些点的比率)。如果绝对峰宽对于数量,摩尔质量和超分布而言是不变的,则可以将该分布明确地分类为泊松分布。这种分布的相对峰宽严格由实验参数确定。已经证明,轴向分散仅导致相对峰宽小于1.25的峰的峰方差加和增加。因此,可以通过使用淬灭的平稳聚合技术或任何其他导致理想泊松分布的技术制备的泊松分布,直接确定实验尺寸排阻色谱仪的轴向分散度。 [参考:23]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号