PURPOSE: To evaluate the performance of the Panomat P-10 micro-volumetric infusion pump for its use in drug administration at minimal flow rates (microL x hr(-1); e.g., intrathecal application). METHODS: Fluid delivery at steady state conditions, and after vertical displacement of the syringe pump by -50 cm was determined gravimetrically. The Panomat P-10 infusion pump was evaluated at 4, 10, 20, 50 and 100 microL x hr(-1), and compared to a conventional syringe pump assembly at 100, 200, 500 and 1000 microL x hr(-1). Measurements were repeated twice with two different devices of each syringe pump system, and with two syringes. Data are reported as mean +/- SD. RESULTS: Steady state fluid delivery of the Panomat P-10 infusion pump revealed less than 5% deviation to set flow rate at 10, 20, 50 and 100 microL x hr(-1), and 12% deviation at 4 microL x hr(-1). Mean zero-drug delivery time (ZDDT) after lowering the pump by 50 cm at 4 microL x hr(-1) flow rate was 38.4 +/- 7.3 min. At 100 microL x hr(-1) andwith original infusion line ZDDT was almost 20 times shorter when compared to the conventional syringe pump assembly (1.5 +/- 0.5 min vs 28.5 +/- 5.0 min). CONCLUSION: The tested Panomat P-10 micro-volumetric pump shows an acceptable flow accuracy as well as a low susceptibility to vertical displacement, and is therefore suitable for continuous drug administration at minimal flow rates. The technology used in this pump carries potential implications for a new generation of syringe pumps.
机译:目的:评估Panomat P-10微体积输液泵以最小流速(microL x hr(-1);例如鞘内应用)用于药物给药的性能。方法:在稳态条件下,以及通过重量分析法确定注射泵垂直位移-50 cm后的流体输送。 Panomat P-10输液泵的评估值为4、10、20、50和100 microL x hr(-1),并与常规注射泵组件的100、200、500和1000 microL x hr(-1)进行比较。 。每个注射器泵系统的两个不同设备和两个注射器重复测量两次。数据报告为平均值+/- SD。结果:Panomat P-10输液泵的稳态输液显示,将流速设置为10、20、50和100 microL x hr(-1)时偏差小于5%,而在4 microL x hr(-1)下的流速偏差为12%。 -1)。在4 microL x hr(-1)流速下将泵降低50 cm后的平均零药递送时间(ZDDT)为38.4 +/- 7.3分钟。与传统的注射泵组件相比,在100 microL x hr(-1)和原始输注线的情况下,ZDDT短了将近20倍(1.5 +/- 0.5分钟vs 28.5 +/- 5.0分钟)。结论:经过测试的Panomat P-10微体积泵显示出可接受的流量精度以及对垂直位移的敏感性低,因此适用于以最小流量连续给药。该泵中使用的技术对新一代注射泵具有潜在的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号