...
首页> 外文期刊>Formosan journal of musculoskeletal disorders. >Use of double-row monolateral Trauma-Fix unibar lengthener for femur lengthening in patients with leg length discrepancy
【24h】

Use of double-row monolateral Trauma-Fix unibar lengthener for femur lengthening in patients with leg length discrepancy

机译:双行单侧Trauma-Fix单杠延长器在腿长差异患者中用于股骨延长

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We report the case of a patient in whom the use of monolateral double-row Trauma-Fix lengthener was successful for femur lengthening after initial difficulty in lengthening by using the single-row lengthener. Problem and case report: A girl 12 years of age presented with a leg-length discrepancy (LLD) of 8 cm and left genu valgum deformity due to a trauma-induced left distal femur physial lesion during her infancy. The patient's weight and height were 38 kg and 148 cm, respectively, and the mechanical axis was 16 degrees of valgus at the time of operation. The lengthening procedure was initiated on postoperative day 7 after the initial correction of the genu valgum deformity. However, no distraction was observed at the osteotomy site, and a convergent angulation deformity developed at the pin-clamp joint. Method and outcome: This problem was resolved successfully with the addition of another row of the Trauma-Fix lengthening device, which was linked via the previously applied pins. A final lengthening of 7.5 cm was achieved in 3 months by using the double-row lengthener without pin tract infection or breakage. The monolateral frame of the Trauma-Fix lengthener was removed in the 11th postoperative month after a solid union of the femur was achieved. The postoperative mechanical axis of the knee was 4 degrees varus. The monolateral double-row lengthener device that showed high efficiency and improved the strength of the ball joints were used along the single-row lengthener, and it may serve as a good alternative for augmentation of insufficient ball joints during limb lengthening.
机译:我们报告了这样的情况:在使用单排加长型延长器最初遇到困难之后,使用单侧双排创伤修复固定剂成功完成了股骨加长。问题和病例报告:12岁的女孩因婴儿时期外伤引起的左股骨远端物理病变而出现8厘米的腿长差异(LLD)和左膝外翻畸形。病人的体重和身高分别为38 kg和148 cm,手术时的机械轴为外翻16度。延长手术时间是在首次纠正外翻畸形后的第7天。然而,在截骨部位未观察到干扰,并且在销夹关节处出现了会聚的成角畸形。方法和结果:通过添加另一排Trauma-Fix加长装置成功解决了该问题,该装置通过先前施加的销钉连接在一起。使用双排加长剂,在3个月内最终伸长7.5 cm,而没有针道感染或断裂。股骨牢固结合后的术后第11个月,将Trauma-Fix延长器的单侧框架取下。膝关节的术后机械轴为4度内翻。沿单行长条使用了具有高效率并提高了球窝接头强度的单边双行长条装置,它可以作为增加肢体加长时不足的球节的很好的选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号