A critical study of the conditions for the direct determination of Cr in urine using GFAAS was carried out. A chemometric approach showed that the most important parameters that influence the efficiency of atomic Cr cloud formation were the atomization from the tube wall and the proper implementation of a pyrolysis step. The established procedure does not require any sample pre-treatment thus minimizing the risk of contamination. The Cr content in urine was determined using a calibration curve prepared with Cr spiked urine, easily correcting all potential matrix interferences. The heating program proposed took 68 s for a 30 #mu#L urine sample. The procedure was applied for the determination of Cr in urine to investigate the absorption rate of Cr picolinate. The limit of detection and the characteristic mass for a 30 #mu#L urine sample were 0.18 #mu#/L and 5.4 pg, respectively.
机译:进行了使用GFAAS直接测定尿液中Cr的条件的严格研究。化学计量学方法表明,影响原子铬云形成效率的最重要参数是管壁的雾化和热解步骤的正确实施。既定的程序不需要任何样品预处理,从而将污染的风险降到最低。尿液中的铬含量可通过使用加标了铬的尿液制成的校准曲线确定,从而轻松校正所有潜在的基质干扰。对于30#mu#L尿液样品,建议的加热程序花费了68 s。该方法用于测定尿液中的Cr,以研究吡啶甲酸铬的吸收率。 30#mu#L尿液样品的检出限和特征质量分别为0.18#mu#/ L和5.4 pg。