The quantitative detennination of trace ele- ments in nuclear samples by GDMSand ~CP-MS is pre- sented and compared. Spectral interferences, matrix ef- fects, detection .limits, precision and accuracy are dis- cussed. Results for selected samples demonstrated that both1echniques are complementary. The use of a multi- standard solution provides the most accurate results in ICP-MS, whereas in GDMS this is achieved by relativ~ sensitivity .factors (RSF) matrix matched. Neveft.heless, the use of standard RSF allows a fast screening.
机译:提出并比较了GDMS和〜CP-MS对核样品中痕量元素的定量测定。讨论了光谱干扰,基质效应,检出限,精确度和准确性。选定样品的结果表明,两种技术是互补的。使用多标准溶液可在ICP-MS中提供最准确的结果,而在GDMS中,这是通过相对灵敏度因子(RSF)矩阵匹配实现的。 Neveft.heless,使用标准RSF可以快速筛查。