A method for qualitative and quantitative determination of paraphenylenediamine in biological fluids (blood, urine and gastric content) was developed. This analytical procedure involves deproteneisation or hydrolysis, liquid-liquid extraction, derivatization with TFA followed by GC-MS iontrap analysis. Benzidine was the internal standard used for quantification and the extraction recovery test was about 85%. The detection limit of paraphenylenediamine was determined at 0.1 pg (S/N=10).
机译:建立了定性和定量测定生物体液(血液,尿液和胃液含量)中对苯二胺的方法。该分析程序涉及脱丙烯或水解,液-液萃取,TFA衍生化,然后进行GC-MS离子阱分析。联苯胺是用于定量的内标,提取回收率试验约为85%。对苯二胺的检出限确定为0.1 pg(S / N = 10)。