A number of pseudo-operational trials were set up to compare the atmospheric/humidity and vacuum cyanoacrylate fuming processes on plastic carrier bags. The fuming processes were compared using two-step cyanoacrylate fuming with basic yellow 40 (BY40) staining and a one-step fluorescent cyanoacrylate fuming, Lumicyano 4%. Preliminary work using planted fingermarks and split depletions were performed to identify the optimum vacuum fuming conditions. The first pseudo-operational trial compared the different fuming conditions (atmospheric/humidity vs. vacuum) for the two-step process where an additional 50% more marks were detected with the atmospheric/humidity process. None of the marks by the vacuum process could be observed visually; however, a significant number of marks were detected by fluorescence after BY40 staining. The second trial repeated the same work in trial 1 using the one-step cyanoacrylate process, Lumicyano at a concentration of 4%. Trial 2 provided comparable results to trial 1 and all the items were then re-treated with Lumicyano 4% at atmospheric/humidity conditions before dyeing with BY40 to provide the sequences of process A (Lumicyano 4% atmospheric-Lumicyano 4% atmospheric-BY40) and process B (Lumicyano 4% vacuum-Lumicyano 4% atmospheric-BY40). The number of marks (visual and fluorescent) was counted after each treatment with a substantial increase in the number of detected marks in the second and third treatments of the process. The increased detection rate after the double Lumicyano process was unexpected and may have important implications. Trial 3 was performed to investigate whether the amount of cyanoacrylate and/or fuming time had an impact on the results observed in trial 2 whereas trial 4 assessed if the double process using conventional cyanoacrylate, rather than Lumicyano 4%, provided an increased detection rate. Trials 3 and 4 confirmed that doubling the amount of Lumicyano 4% cyanoacrylate and fuming time produced a lower detection rate than the double process with Lumicyano 4%. Furthermore, the double process with conventional cyanoacrylate did not provide any benefit. Scanning electron microscopy was also performed to investigate the morphology of the cyanoacrylate polymer under different conditions.
机译:建立了许多模拟操作试验,以比较塑料袋上的大气/湿度和氰基丙烯酸酯真空熏制工艺。使用两步氰基丙烯酸酯发烟(带有碱性黄40(BY40)染色)和一步荧光氰基丙烯酸酯发烟(Lumicyano 4%)对发烟过程进行了比较。进行了初步的工作,其中使用了种植的指印并进行了分光处理,以确定最佳的真空发烟条件。第一次伪操作试验比较了两步过程的不同发烟条件(大气/湿度与真空),其中大气/湿度过程中另外检测到50%的痕迹。真空过程中没有任何痕迹可以目视观察到;然而,BY40染色后通过荧光检测到大量标记。第二个试验使用一步法氰基丙烯酸酯工艺Lumicyano以4%的浓度重复了试验1中的相同工作。试验2提供了与试验1相当的结果,然后所有物品在大气/湿度条件下用4%的Lumicyano重新处理,然后用BY40染色,以提供工艺A的顺序(Lumicyano 4%大气-Lumicyano 4%大气-BY40)和方法B(Lumicyano 4%真空-Lumicyano 4%常压-BY40)。每次处理后计数标记(视觉和荧光)的数量,在该过程的第二和第三次处理中,检测到的标记的数量大大增加。两次Lumicyano处理后检测率的提高是出乎意料的,可能具有重要意义。进行试验3以研究氰基丙烯酸酯的量和/或发烟时间是否对试验2中观察到的结果有影响,而试验4评估了使用常规氰基丙烯酸酯而不是4%的Lumicyano的双重工艺是否可以提高检测率。实验3和4证实,与4%Lumicyano相比,将Lumicyano 4%氰基丙烯酸酯量加倍和发烟时间产生的检出率较低。此外,使用常规氰基丙烯酸酯的双重工艺没有提供任何益处。还进行了扫描电子显微镜以研究在不同条件下氰基丙烯酸酯聚合物的形态。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号