首页> 外文期刊>Forensic science international >Detection of piperonal emitted from polymer controlled odor mimic permeation systems utilizing Canis familiaris and solid phase microextraction-ion mobility spectrometry.
【24h】

Detection of piperonal emitted from polymer controlled odor mimic permeation systems utilizing Canis familiaris and solid phase microextraction-ion mobility spectrometry.

机译:利用犬类和固相微萃取-离子淌度光谱技术检测聚合物控制的气味模拟渗透系统发出的胡椒醛。

获取原文
获取原文并翻译 | 示例
       

摘要

Currently, in the field of odor detection, there is generally a wider variation in limit of detections (LODs) for canines than instruments. The study presented in this paper introduces an improved protocol for the creation of controlled odor mimic permeation system (COMPS) devices for use as standards in canine training and discusses the canine detection thresholds of piperonal, a starting material for the illicit drug 3,4-methylenedioxymethamphetamine (MDMA), when exposed to these devices. Additionally, this paper describes the first-ever reported direct comparison of solid phase microextraction-ion mobility spectrometry (SPME-IMS) to canine detection for the MDMA odorant, piperonal. The research presented shows the reliability of COMPS devices as low cost field calibrants providing a wide range of odorant concentrations for biological and instrumental detectors. The canine LOD of piperonal emanating from the 100 ng s(-1) COMPS was found to be 1 ng as compared to the SPME-IMS LOD of piperonal in a static, closed system at 2 ng, with a linear dynamic range from 2 ng to 11 ng. The utilization of the COMPS devices would allow for training that will reduce the detection variability between canines and maintain improved consistency for training purposes. Since both SPME and IMS are field portable technologies, it is expected that this coupled method will be useful as a complement to canine detection for the field detection of MDMA.
机译:当前,在气味检测领域中,犬类的检测极限(LOD)通常比仪器具有更大的变化。本文提出的研究介绍了一种改进的协议,用于创建受控气味模拟渗透系统(COMPS)设备,该设备用作犬训练的标准,并讨论了作为非法药物3,4-起始原料的胡椒醛的犬检出阈值。亚甲基二氧基甲基苯丙胺(MDMA),当暴露于这些设备时。此外,本文描述了有史以来首次报道的固相微萃取-离子淌度光谱法(SPME-IMS)与犬MDMA加味剂胡椒醛检测的直接比较。提出的研究表明,COMPS设备的可靠性,因为它是低成本的现场校准剂,可为生物和仪器检测器提供广泛的气味浓度。与静态,封闭系统中2 ng的线性,线性动态范围为2 ng的闭式系统中,从100 ng s(-1)COMPS发出的犬的LOD相比,SPME-IMS LOD为1 ng。至11 ng。利用COMPS设备可以进行培训,这将减少犬之间的检测变异性,并为培训目的保持更好的一致性。由于SPME和IMS都是现场便携式技术,因此可以预期,这种耦合方法将可作为犬检测MDMA现场检测的补充。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号