首页> 外文期刊>Food Control >Determination of cadmium(II) and zinc(II) in olive oils by derivative potentiometric stripping analysis
【24h】

Determination of cadmium(II) and zinc(II) in olive oils by derivative potentiometric stripping analysis

机译:导数电位溶出分析法测定橄榄油中的镉和锌(II)

获取原文
获取原文并翻译 | 示例
           

摘要

A method for the determination of cadmium(II) and zinc(II) in olive oils by derivative potentiometric stripping analysis after dry ashing of the sample is described. The metal ions were concentrated as their amalgams on the glassy carbon working electrode that was previously coated with a thin mercury film and then stripped by a suitable oxidant. Potential and time data were digitally converted into dt dE(-1), and E was plotted vs. dt dE(-1), thus increasing sensitivity of the method and improving resolution of the analysis. Quantitative analysis was carried out by the method of standard additions; a good linearity was obtained in the range of concentrations examined. Recoveries of 92-102% for cadmium(II) and of 89-99% for zinc(II) were obtained from an olive oil spiked at different levels. The detection limits were 5.1 ngg(-1) for cadmium(II) and 7.6 ngg(-1) for zinc(II) and the relative standard deviations (mean of nine determinations) were 4.1% and 5.2%, respectively. Results obtained on commercial olive oils were not significantly different from those obtained by inductively coupled plasma atomic emission spectrometry (ICP-AES).
机译:描述了一种在样品干灰化后通过导数电位溶出分析法测定橄榄油中镉(II)和锌(II)的方法。金属离子以汞齐的形式浓缩在玻璃碳工作电极上,该电极预先涂有一层薄汞膜,然后用合适的氧化剂剥离。将电势和时间数据数字转换为dt dE(-1),并绘制E与dt dE(-1)的关系图,从而提高了方法的灵敏度并提高了分析的分辨率。定量分析采用标准添加法进行。在所检查的浓度范围内获得了良好的线性。从添加了不同含量的橄榄油中,镉(II)的回收率为92-102%,锌(II)的回收率为89-99%。镉(II)的检出限为5.1 ngg(-1),锌(II)的检出限为7.6 ngg(-1),相对标准偏差(九次测定的平均值)分别为4.1%和5.2%。在商用橄榄油上获得的结果与通过电感耦合等离子体原子发射光谱法(ICP-AES)获得的结果没有显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号