...
首页> 外文期刊>Food analytical methods >Development of a new extraction method for heterocyclic aromatic amines determination in cooked meatballs.
【24h】

Development of a new extraction method for heterocyclic aromatic amines determination in cooked meatballs.

机译:开发了一种新的提取方法,用于测定熟肉丸中的杂环芳族胺。

获取原文
获取原文并翻译 | 示例
           

摘要

Heterocyclic aromatic amines (HCAs) are mutagenic and carcinogenic compounds that are produced in meats cooked at high temperature. In this study, 2-amino-3-methylimidazo[4,5-f]quinoline (IQ), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx), 2-amino-3,4,8-trimethylimidazo[4,5-f]quinoxaline (4,8-DiMeIQx), 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP), 9H-pyrido[3,4-b]indole (norharman), and 1-methyl-9H-pyrido[3,4-b]indole (harman) were studied. A new extraction method was developed for the determination of heterocyclic amines with high-performance liquid chromatography (HPLC). Linearity for each HCA was observed with a high regression coefficient (r = 0.9999, P < 0.01 for IQ; r = 0.9990, P < 0.01 for MeIQx; r = 0.9989, P < 0.01 for 4,8-DiMeIQx; r = 0.9934, P < 0.05 for PhIP; r = 1.000, P< 0.01 for norharman; r = 0.9991, P < 0.01 for harman). Limits of detection for various HCAs were found between 0.04 and 1.40 ng/g. Limits of quantification were found in the range of 0.13-4.40 ng/g. Recovery rates varied from 68.9 % to 87.8 %. This method was compared with two different common HCA extraction methods in literature. The optimized new extraction method and the other two methods were used for the determination of HCAs in ten different cooked meatball samples. Sample extraction procedures of HCAs were investigated in more detail, and a rapid, accurate, precise, and reliable extraction method was developed. copyright Springer Science+Business Media New York 2013.
机译:杂环芳香胺(HCA)是在高温下烹煮的肉类中产生的诱变和致癌化合物。在这项研究中,2-氨基-3-甲基咪唑并[4,5-f]喹啉(IQ),2-氨基-3,8-二甲基咪唑并[4,5-f]喹喔啉(MeIQx),2-氨基-3, 4,8-三甲基咪唑并[4,5-f]喹喔啉(4,8-DiMeIQx),2-氨基-1-甲基-6-苯基咪唑并[4,5-b]吡啶(PhIP),9H-吡啶并[3,研究了4-b]吲哚(norharman)和1-甲基-9H-吡啶并[3,4-b]吲哚(harman)。开发了一种新的萃取方法,用高效液相色谱法(HPLC)测定杂环胺。观察到每个HCA的线性都具有较高的回归系数(r = 0.9999,IQ P <0.01; r = 0.9990,MeIQx P <0.01; r = 0.9989,4,8-DiMeIQx P <0.01; r = 0.9934,对于PhIP,P <0.05;对于Norharman,r = 1.000,P <0.01;对于Harman,r = 0.9991,P <0.01)。发现各种HCA的检出限在0.04至1.40 ng / g之间。发现的定量限为0.13-4.40 ng / g。回收率从68.9%到87.8%不等。将该方法与文献中两种不同的常见HCA提取方法进行了比较。优化的新提取方法和另外两种方法用于测定十种不同的熟肉丸样品中的HCA。对HCA的样品提取程序进行了更详细的研究,并开发了一种快速,准确,精确和可靠的提取方法。版权所有Springer Science + Business Media纽约,2013年。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号